Order No
101167896
Article Code
101167896
Certificates
TÜV cULus UKCA
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Sensörleri
CSS 8-180-2P-E-L
Product Description
- • IP Rating: IP65/IP67 | Voltage: 24 VDC | Weight: 137 g | Cable: 1 m | PL e
Standards
- • EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508
Product Features
- • Pre-wired cable 4-pole_x000D_
- • Termoplastik gövde_x000D_
- • Elektronik temazsız kodlu sistem_x000D_
- • Misaligned actuation possible_x000D_
- • High repeat accuracy of the switching points_x000D_
- • Sensör zincirinin maks. uzunluğu 200 m_x000D_
- • Early warning when operating near the limit of the sensor's hysteris range_x000D_
- • Self-monitoring series-wiring of 16 sensors_x000D_
- • 2 short-circuit proof PNP safety outputs
Technical Specifications
PIN 1
A1 Ue Brown
PIN 2
Y2 safety output 2: Beyaz
PIN 3
A2 GND Blue
PIN 4
Y1 Safety output 1 Black
Category
4
General Note
Evaluation gereksinimleri: dual channel safety input, NA fonksiyonlu p-type sensor for suitable. Safety monitoring module sensor exit maks.
Active Area
Cam elyaf takviyeli termoplastik
Wire Cross-Section
20 AWG
PFH Value
3.57 x 10⁻⁹ /h
Impact Resistance
30 g / 11 ms
Mission Time
20 Year(s)
Max. Hysteresis
0.7 mm
Cable Length
1 m
Nut Material
Cam elyaf takviyeli termoplastik
Gross Weight
137 g
Housing Material
Cam elyaf takviyeli termoplastik
Protection Class
II
Pollution Degree
3
Sensor ISO Thread
M18
Sensor Length
92 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 55 Hz, amplitude 1 mm
Max. Risk Time
30 ms
Sensor Topology
Tekil sensor or serideki son sensor
Operating Current
1,000 mA
Switch Width
24 BK
IP Protection Class
IP65 IP67
Short-Circuit Detection
Yes
Max. Response Time
30 ms
Ambient Temperature
-25 ... +60 °C
Performance Level
e
Operating Voltage
24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle
inductive
Housing Design Form
Threaded cylinder
Recommendation (Actuator)
CST 180-1 CST 180-2
Repeat Accuracy R
0.2 mm
Cross-Circuit Detection
Yes
Terminal Connection
Cable
Max. Leakage Current (Ir)
0.5 mA
Suitable SIL Applications
3
Safety Functions
Yes
Max. Nut Tightening Torque
3 Nm
Current Utilization Cat. DC-12
0.5 A
Current Utilization Cat. DC-13
0.5 A
Mechanical Mounting Conditions
Embedded not
Note (Switching Distance)
All switching distances EN IEC 60947-5-3'e is according to
Typical Switching Distance
8 mm
Overvoltage Category
III
Rated Operating Voltage
24 VDC
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
Guaranteed Opening Distance (ON) Sao
7 mm
Max. Voltage Drop (Ud)
0.5 V
Number of Sensors Connected in Series
16
Terminal Connector Output
4-pole
Impulse Withstand Voltage (Uimp)
0.8 kV
Guaranteed Opening Distance (OFF) Sar
10 mm
Control Elements Design
p-tipi
Storage/Transport Temperature
-25 ... +85 °C
Integrated System Diagnostics Status
Yes
Recommended Safety Switch
PROTECT PSC1 SRB-E-301ST SRB-E-201LC
Approximate Switching Frequency
3 Hz
Rated Insulation Voltage (Uᵢ)
32 VDC
Mounting Material Scope of Delivery
2x nuts M18 x 1
Number of Safe Digital Outputs
2
Typical Idle Operating Current (I₀)
50 mA
Max. Output Current (Safe Output)
0.5 A
Note (LED Switching Condition Indication)
Multi-coloured LED: Green, Red, Yellow
Rated Operating Current (Safety Outputs)
500 mA