EX-BNS 250-11Z-3G/D 5,0M
Order No 101187078
Article Code 101187078
Certificates ATEX (Konformitätserklärung)
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Sensörleri

EX-BNS 250-11Z-3G/D 5,0M

Product Description

  • IP Rating: IP67 | Weight: 198 g | Cable: 5 m | Contacts: 1 NC, 1 NO

Standards

  • EN ISO 13849-1

Product Features

  • ATEX Zon 2 ve 22 için patlama koruması_x000D_
  • Termoplastik gövde_x000D_
  • Yanal hizasızlığa karşı duyarsız_x000D_
  • Mekanik aşınma yok_x000D_
  • 64 mm x 29.5 mm x 15.5 mm (incl. protective enclosure)

Technical Specifications

Coding Yes
General Note Contact sembolleri guard of the device closed condition for is shown. LED'li/LED'siz of the versions contact configuration is the same.
Active Area front taraf
Wire Cross-Section 23 AWG
Impact Resistance 30 g / 11 ms
Mission Time 20 Year(s)
Direction of Movement Active to the surface vertical
Cable Length 5 m
Gross Weight 198 g
Housing Material Cam elyaf takviyeli termoplastik
Manufacturer Declaration ATEX Zone 2 and 22
Sensor Length 13 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 55 Hz, amplitude 1 mm
Number of Cable Wires 4
Actuation Element Magnet
IP Protection Class IP67
Ambient Temperature -25 ... +70 °C
Sensor Width 33 mm
Switching Element 1 NA contact, 1 NK contact
Switching Principle Reed contacts, non-contact prensip
Max. Impact Energy 7 J
Housing Design Form Blok
Sensor Height 25 mm
Recommendation (Actuator) EX-BPS 250-3G/D
Terminal Connection Cable
Explosion Protection Definition D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X
B10D NC/NA Contact Value 25,000,000 Cycles
Cable Sheath Material PVC
Max. Switching Current 0.1 A
Explosion Protection Zones 2 22
Explosion Protection Category 3G 3D
Max. Switching Voltage 24 VDC
Mechanical Mounting Conditions Embedded not
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Max. Switching Capacity 1 W
Guaranteed Opening Distance (ON) Sao 4 mm
Guaranteed Opening Distance (OFF) Sar 14 mm
Explosion Protection Regulations EN IEC 60079-0 EN IEC 60079-15 EN 60079-31
Storage/Transport Temperature -25 ... +70 °C
Recommended Safety Switch SRB-E-301ST SRB-E-201LC
Precondition Evaluation Unit Yes
Max. Switching Frequency (Approx.) 5 Hz
Number of NO (Normally Open) Contacts 1
Number of NC (Normally Closed) Contacts 1