Order No
101181693
Article Code
101181693
Certificates
cULus
Schmersal
Emniyetli Sinyal İşleme
Güvenlik Rölesi ve Kontrol Modülleri
FWS 2505 A UE: 24...230V AC/DC
Product Description
- • Voltage: 24 ... 230 VAC | Dimensions: 45mm×100mm×121mm | Weight: 355 g | Certification: cULus | PL d
Standards
- • EN IEC 61508
Product Features
- • Detects standstill using 2 impulse sensor(s)_x000D_
- • 4 safety contacts_x000D_
- • 1 sinyal çıkışı_x000D_
- • 2 additional transistor outputs
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Depth
121 mm
Category
3
Faults
Hinge ekseni 11 mm above must be. SW 2 mm (a and b) hexagon anahtar with minimum 50 mm actuation radius.
General Note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
45 mm
Height
100 mm
PFH Value
1.00 x 10⁻⁷ /h
Number of LEDs
1
Impact Resistance
30 g / 11 ms
Application Note
Safe durma monitoring
Mission Time
20 Year(s)
Gross Weight
355 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact Material
Ag-Ni 10 and 0,2 µm gold coated
Pollution Degree
2
Min. Cable Cross-Section
0.2 mm²
Vibration Resistance
10 ... 55 Hz, Amplitude 0.35 mm
Clip Tightening Torque
0.6 Nm
Max. Cable Cross-Section
2.5 mm²
Climatic Resistance
EN 60068-2-3 BG-GS-ET-14
Stop Category
0
Ambient Temperature
+0 ... +55 °C
Performance Level
d
Operating Voltage
24 ... 230 VAC 24 ... 230 VDC
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical Life (min.)
20,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Reset When Power is Removed
Yes
Max. Transmission Resistance
40 Ω
Note (ISD - Faults)
The following fault safety monitoring modules by kaydedilir and ISD by is shown.
Wire Breakage Detection
Yes
Terminal Connection
Solid or esnek, threaded terminal block M20 x 1,5
Voltage Range Type
AC DC
Suitable SIL Applications
2
Connection Diagram Note
Connection diagram, guard door closed and enerji cut off in the state is shown. ISD tables in the appendix. Guard door monitoring.
Number of Safety Contacts
4
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
0.125
Current Utilization Cat. DC-13
0.08333333333212067
Number of Auxiliary Contacts
1
Overvoltage Category
III
Min. Switching Capacity
10 mA
Rated Operating Voltage
24 ... 230 VAC 24 ... 230 VDC
Number of Signal Outputs
2
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
0.08333333333212067
AC Control Voltage 50Hz max.
253 VAC
AC Control Voltage 60Hz max.
253 VAC
Input Signal LOW (Signal 0)
0 … 2 VDC
Impulse Withstand Voltage (Uimp)
4.8 kV
Input Signal HIGH (Signal 1)
10 … 30 VDC
Storage/Transport Temperature
-25 ... +70 °C
Integrated System Diagnostics Status
Yes
DC Min. Rated Control Voltage
20.4 VDC
DC Max. Rated Control Voltage
253 VDC
Max. Electrical Power Consumption
5 W
Number of Undelayed Semiconductor Outputs (with Signal Function)
2