Order No
101138576
Article Code
101138576
Certificates
cULus
Schmersal
Emniyetli Sinyal İşleme
Güvenlik Rölesi ve Kontrol Modülleri
AES 3075 24 VDC
Product Description
- • Voltage: 24 VDC | Dimensions: 75mm×100mm×110mm | Weight: 379 g | Certification: cULus | Contacts: 4 NC, 4 NO | PL d
Standards
- • EN ISO 13849-1 EN IEC 61508
Product Features
- • BNS serisi manyetik güvenlik sensörü izleme_x000D_
- • 2 güvenlik kontağı, STOP 0_x000D_
- • 4 sinyal çıkışı
Technical Specifications
Note
All belirtimler iletken end included.
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
maks. 50.000 switching cycle/year and maks. %80 contact load for
Depth
110 mm
Category
3
Faults
Door contact not opening or not closing.; Switch connection cross cable or short devre monitoring.; Switch connection kesilmesi.
General Note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
75 mm
Height
100 mm
PFH Value
1.00 x 10⁻⁷ /h
Number of LEDs
1
Impact Resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor Guard system
Mission Time
20 Year(s)
Gross Weight
379 g
Housing Material
Cam elyaf takviyeli termoplastik
Start Input
Yes
Pollution Degree
2
Vibration Resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.4 Nm
Max. Cable Cross-Section
4 mm²
Terminal (Mechanical)
Threaded terminal block
Ripple Voltage
0.1
Stop Category
0
Ambient Temperature
+0 ... +55 °C
Performance Level
d
Thermal Test Current
0.16666666666787933
Operating Voltage
24 VAC -15 % / +10 % 24 VDC -15 % / +40 %
Feedback Circuit
Yes
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Note (Contact Resistance)
In new condition
Max. Transmission Resistance
40 Ω
Note (ISD - Faults)
The following fault safety monitoring modules by kaydedilir and ISD by is shown.
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Suitable SIL Applications
2
Connection Diagram Note
Connection diagram, guard door closed and enerji cut off in the state is shown. ISD tables in the appendix. PL d and Category 3'e up to.
Number of Safety Contacts
2
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
0.25
Current Utilization Cat. DC-12
0.1 A
Current Utilization Cat. DC-13
0.25
Overvoltage Category
III
Electrical Power Consumption
8 W
Min. Switching Capacity
10 mA
Rated Operating Voltage
24 VDC
Number of Signal Outputs
4
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
0.08333333333212067
AC Control Voltage 50Hz max.
26.4 VAC
AC Control Voltage 60Hz max.
26.4 VAC
Input Signal LOW (Signal 0)
0 … 2 VDC
Impulse Withstand Voltage (Uimp)
0.5 kV
Input Signal HIGH (Signal 1)
10 … 30 VDC
Emergency Release Delay
20 ms
Storage/Transport Temperature
-25 ... +70 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
DC Min. Rated Control Voltage
20.4 VDC
DC Max. Rated Control Voltage
28.8 VDC
Number of NO (Normally Open) Contacts
4
Release Delay on Power Failure
80 ms
Number of NC (Normally Closed) Contacts
4
Pull-In Delay on Automatic Start
100 ms
Number of Undelayed Semiconductor Outputs (with Signal Function)
4