AES 3075 24 VDC
Order No 101138576
Article Code 101138576
Certificates cULus
Schmersal Emniyetli Sinyal İşleme Güvenlik Rölesi ve Kontrol Modülleri

AES 3075 24 VDC

Product Description

  • • Voltage: 24 VDC | Dimensions: 75mm×100mm×110mm | Weight: 379 g | Certification: cULus | Contacts: 4 NC, 4 NO | PL d

Standards

  • • EN ISO 13849-1 EN IEC 61508

Product Features

  • • BNS serisi manyetik güvenlik sensörü izleme_x000D_
  • • 2 güvenlik kontağı, STOP 0_x000D_
  • • 4 sinyal çıkışı

Technical Specifications

Note All belirtimler iletken end included.
Mounting Fits onto a standard DIN rail per EN 60715
Warning maks. 50.000 switching cycle/year and maks. %80 contact load for
Depth 110 mm
Category 3
Faults Door contact not opening or not closing.; Switch connection cross cable or short devre monitoring.; Switch connection kesilmesi.
General Note Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width 75 mm
Height 100 mm
PFH Value 1.00 x 10⁻⁷ /h
Number of LEDs 1
Impact Resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Safety sensor Guard system
Mission Time 20 Year(s)
Gross Weight 379 g
Housing Material Cam elyaf takviyeli termoplastik
Start Input Yes
Pollution Degree 2
Vibration Resistance 10...55 Hz, Amplitude 0.35 mm, ± 15 %
Frequency Range 50 Hz 60 Hz
Clip Tightening Torque 0.4 Nm
Max. Cable Cross-Section 4 mm²
Terminal (Mechanical) Threaded terminal block
Ripple Voltage 0.1
Stop Category 0
Ambient Temperature +0 ... +55 °C
Performance Level d
Thermal Test Current 0.16666666666787933
Operating Voltage 24 VAC -15 % / +10 % 24 VDC -15 % / +40 %
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Note (Contact Resistance) In new condition
Max. Transmission Resistance 40 Ω
Note (ISD - Faults) The following fault safety monitoring modules by kaydedilir and ISD by is shown.
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Suitable SIL Applications 2
Connection Diagram Note Connection diagram, guard door closed and enerji cut off in the state is shown. ISD tables in the appendix. PL d and Category 3'e up to.
Number of Safety Contacts 2
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. AC-15 0.25
Current Utilization Cat. DC-12 0.1 A
Current Utilization Cat. DC-13 0.25
Overvoltage Category III
Electrical Power Consumption 8 W
Min. Switching Capacity 10 mA
Rated Operating Voltage 24 VDC
Number of Signal Outputs 4
AC Control Voltage 50Hz min. 20.4 VAC
AC Control Voltage 60Hz min. 20.4 VAC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 0.08333333333212067
AC Control Voltage 50Hz max. 26.4 VAC
AC Control Voltage 60Hz max. 26.4 VAC
Input Signal LOW (Signal 0) 0 … 2 VDC
Impulse Withstand Voltage (Uimp) 0.5 kV
Input Signal HIGH (Signal 1) 10 … 30 VDC
Emergency Release Delay 20 ms
Storage/Transport Temperature -25 ... +70 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 20 ms
DC Min. Rated Control Voltage 20.4 VDC
DC Max. Rated Control Voltage 28.8 VDC
Number of NO (Normally Open) Contacts 4
Release Delay on Power Failure 80 ms
Number of NC (Normally Closed) Contacts 4
Pull-In Delay on Automatic Start 100 ms
Number of Undelayed Semiconductor Outputs (with Signal Function) 4