AZ 200ST-T-AS
Order No 101190950
Article Code 101190950
Certificates cULus ASi-SaW
Schmersal Sistem Çözümleri AS-i Güvenlik Sistemi

AZ 200ST-T-AS

Product Description

  • • IP Rating: IP67 | Voltage: 26.5 ... 31.6 VDC | Weight: 335 g | Certification: cULus ASi-SaW | PL e

Standards

  • • EN IEC 60947-5-3 EN IEC 61508

Product Features

  • • Safety switch with separate actuator_x000D_
  • • Termoplastik gövde_x000D_
  • • Entegre AS-Interface_x000D_
  • • 40 mm x 220 mm x 50 mm_x000D_
  • • Çalışma koşullarını gösteren 3 LED_x000D_
  • • Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally_x000D_
  • • Akıllı diagnostik_x000D_
  • • With door detection sensor T_x000D_
  • • Koruma sınıfı IP67

Technical Specifications

Note Torx T10
PIN 1 AS-i +
PIN 2 n.c. (≤ 30 VDC)
PIN 3 AS-Interface -
PIN 4 n.c. (≤ 30 VDC)
Category 4
PFH Value 4.00 x 10⁻⁹ /h
AS-i ID Code 0xB
AS-i IO Code 0x0
AS-i Profile S-0.B.F.E
Impact Resistance 30 g / 11 ms
AS-i ID Code 1 0xF
AS-i ID Code 2 0xE
AS-i Version V 2.1
Mission Time 20 Year(s)
Max. Hysteresis 1.5 mm
Current Consumption 50 mA
Gross Weight 335 g
Housing Material Cam elyaf takviyeli termoplastik
Protection Class II
Min. Relative Humidity 0.3
Locking Force 30 N
Pollution Degree 3
Max. Relative Humidity 0.95
Note (Relative Humidity) Non-condensing
Sensor Length 50 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 55 Hz, amplitude 1 mm
Max. Risk Time 120 ms
IP Protection Class IP67
Max. Response Time 60 ms
Ambient Temperature -25 ... +70 °C
Performance Level e
Sensor Width 40 mm
Operating Principle Non-contact
Actuator Monitored Yes
Mechanical Life (min.) 1,000,000 Cycles
Sensor Height 220 mm
Repeat Accuracy R 0.5 mm
AS-i Input Channel 1 Veri bitleri DI 0 / DI 1 = dinamik kod iletimi
AS-i Input Channel 2 Veri bitleri DI 2 / DI 3 = dinamik kod iletimi
Terminal Connection M12 connector plug, 4 pole (A coded)
Max. Actuation Speed 0.2 m/s
Suitable SIL Applications 3
Safety Functions Yes
AS-i Parameter Bits P0 Guard door and actuator detected
AS-i Parameter Bits P1 Safety lock opening
AS-i Parameter Bits P2 Static 0
AS-i Parameter Bits P3 Error
Max. Ready Time 4,000 ms
AS-i Output DO 0...DO 3 No function
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Typical Switching Distance 6.5 mm
AS-i Input Module Address 0
Overvoltage Category III
Rated Operating Voltage 26.5 ... 31.6 VDC (Reverse polarity protection)
Note (AS-i Parameter Bits) Set the parameter outputs to "1111" (0xF). FID: peripheral error
Guaranteed Opening Distance (ON) Sao 4 mm
Impulse Withstand Voltage (Uimp) 0.8 kV
Guaranteed Opening Distance (OFF) Sar 30 mm
Storage/Transport Temperature -25 ... +85 °C
Integrated System Diagnostics Status Yes
Rated Insulation Voltage (Uᵢ) 32 VDC
Note (AS-i Input Module Address) Adres 0'a front set; AS-interface bus master or el type programlama device with changeable
Housing Cover Screw Torque (Min.) 0.7 Nm
Housing Cover Screw Torque (Max.) 1 Nm
Note (LED Switching Condition Indication) (1) Green-red LED (AS-i Duo LED): Supply voltage / Communication error / Slave address = 0 (2) Red LED: Internal device error (3) Yellow LED: Device status