AZM300B-ST-1P2P-N
Order No 103006867
Article Code 103006867
Certificates TÜV cULus ECOLAB FCC IC ANATEL UKCA
Schmersal Emniyetli Anahtarlama ve Denetleme Solenoid Kilitler

AZM300B-ST-1P2P-N

Product Description

  • • IP Rating: IP66/IP67/IP69 | Voltage: 24 VDC | Weight: 650 g | PL e

Standards

  • • EN ISO 13849-1 EN IEC 61508

Product Features

  • • Universal coding with RFID technology_x000D_
  • • Connector M12, 8-pole_x000D_
  • • Açmak için güç gerekli_x000D_
  • • Actuator monitored_x000D_
  • • Diagnostik çıkış_x000D_
  • • Acil serbest bırakma_x000D_
  • • Hijyenik tasarım_x000D_
  • • Protection class IP 69_x000D_
  • • Suitable for mounting to profile systems_x000D_
  • • Termoplastik gövde_x000D_
  • • İhtiyaca dayalı müdahale koruması için RFID teknolojisi_x000D_
  • • 3 different directions of actuation_x000D_
  • • Kompakt tasarım_x000D_
  • • Çalışma koşullarını gösteren 3 LED_x000D_
  • • Menteşeli ve kızaklı koruyucular için uygun_x000D_
  • • Series-wiring_x000D_
  • • Manuel açma

Technical Specifications

PIN 1 A1 Supply voltage UB
PIN 2 X1 Safety input 1
PIN 3 A2 GND
PIN 4 Y1 Safety output 1
PIN 5 OUTPUT Diagnostics output
PIN 6 X2 Safety input 2
PIN 7 Y2 Safety output 2
PIN 8 INPUT Solenoid control
Coding Universal coding
Category 4
General Note For doors flush with the door frame, the optional MP-AZ/AZM300-1 mounting plate can be used. For glass and Makrolon doors, the optional MS-AZ/AZM300-B1-1 mounting kit can be used.
PFD Value 4.50 x 10⁻⁵
PFH Value 5.20 x 10⁻¹⁰ /h
Impact Resistance 30 g / 11 ms
Latching Yes
Mission Time 20 Year(s)
Series Connection Yes
Gross Weight 650 g
Housing Material Cam elyaf takviyeli termoplastik
Protection Class III
Pollution Degree 3
Max. Relative Humidity 0.93
Note (Relative Humidity) Non-condensing, non-icing
Sensor Length 146 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 150 Hz, amplitude 0.35 mm
Force to Open Yes
Max. Risk Time 200 ms
Operating Current 800 mA
24V Current Consumption 5 mA
IP Protection Class IP66 IP67 IP69
Short-Circuit Detection Yes
Ambient Temperature +0 ... +60 °C
Performance Level e
RFID Frequency Band 125 kHz
Sensor Width 87.5 mm
Operating Voltage 24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle RFID
Actuator Monitored Yes
Mechanical Life (min.) 1,000,000 Cycles
Note (Mechanical Life) When used as a door stop: ≥ 50,000 cycles (door mass ≤ 5 kg and actuation speed ≤ 0.5 m/s)
Sensor Height 55 mm
Recommendation (Actuator) AZ/AZM300-B1
Emergency Release Yes
Switching Thresholds −3 V … 5 V (Low) 15 V … 30 V (High)
Note (Series Connection) Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Cross-Circuit Detection Yes
Fixing Screw Type 2x M6
Terminal Connection Connector M12, 8-pole, A-coded
Max. Leakage Current (Ir) 0.5 mA
Suitable SIL Applications 3
Safety Functions Yes
Max. Installation Altitude 3,000 m
Max. Test Pulse Duration 0.5 ms
Max. Holding Force Fmax 1,500 N
Max. Ready Time 5,000 ms
Number of Actuation Directions 3
Current Utilization Cat. DC-12 0.05 A
Current Utilization Cat. DC-13 0.05 A
Utilization Category DC-12 24 VDC / 0.05 A
Min. Test Pulse Interval 100 ms
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Typical Switching Distance 2 mm
Overvoltage Category III
Magnet Release Time 1
Rated Operating Voltage 24 VDC
Typical Test Pulse Interval 1000 ms
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
Min. Fixing Screw Torque 6 Nm
Guaranteed Opening Distance (ON) Sao 1 mm
Safety Inputs Definition X1 and X2
Max. Voltage Drop (Ud) 2 V
Max. Fixing Screw Torque 7 Nm
Max. Transmitter RFID Output -6 dBm
Magnet Control Definition IN
Impulse Withstand Voltage (Uimp) 0.8 kV
Guaranteed Opening Distance (OFF) Sar 20 mm
Control Elements Design Short devre resistant, p-type
Storage/Transport Temperature -10 ... +90 °C
Integrated System Diagnostics Status Yes
Locking Force Adjustment Position 1 25 N
Locking Force Adjustment Position 2 50 N
Coding Level (EN ISO 14119) Low
Max. Sensor Chain Length 200 m
Note (Sensor Chain Length) Cable length and cross-section change the voltage drop depending on the output current
Holding Force FZh (EN ISO 14119) 1,150 N
Safety Outputs Definition Y1 and Y2
Max. Electrical Fuse Rating 0.08333333333212067
Rated Insulation Voltage (Uᵢ) 32 VDC
Diagnostic Outputs Definition OUT
Max. Switching Frequency (Approx.) 0.5 Hz
Required Rated Short-Circuit Current 100 A
Number of Safe Digital Outputs 2
External Wire and Device Fuse Rating 2 A gG
Magnet ON Peak Current Consumption 350 mA / 200 ms
ZVEI CB24I Sink Classification C1 C2
ZVEI CB24I Source Classification C2
Magnet ON Average Current Consumption 200 mA
Typical Idle Operating Current (I₀) 100 mA
Note (LED Switching Condition Indication) Operating status: LED green / Fault / functional failure: LED red / Supply voltage UB: LED green
Max. Solenoid Lock-Actuator Angular Misalignment 2 °
Max. Response Time (Actuator to Safety Output Off) 100 ms
Max. Response Time (Safety Input to Safety Output Off) 1.5 ms
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.