BNS 260 AS-L
Order No 101186154
Article Code 101186154
Certificates cULus ASi-SaW
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Sensörleri

BNS 260 AS-L

Product Description

  • • IP Rating: IP67 | Voltage: 18 ... 31.6 VDC | Weight: 76 g | Cable: 2 m | Certification: cULus ASi-SaW | PL e

Standards

  • • EN IEC 61508

Product Features

  • • 2 m Pre-wired cable, 2-pole_x000D_
  • • Safety sensor_x000D_
  • • Termoplastik gövde_x000D_
  • • Mekanik aşınma yok_x000D_
  • • 36 mm x 26 mm x 13 mm_x000D_
  • • Entegre AS-Interface_x000D_
  • • Gizli montaj mümkün_x000D_
  • • Uzun ömürlü_x000D_
  • • Yanal hizasızlığa karşı duyarsız_x000D_
  • • Kirlenmeye karşı duyarsız_x000D_
  • • AS-Interface LED and status display

Technical Specifications

PIN 1 Brown (AS interface +)
PIN 2 n.c.
PIN 3 Blue (AS interface −)
PIN 4 n.c.
Coding Yes
Category 4
Cable Type LSYY
Wire Cross-Section 23 AWG
PFH Value 6.21 x 10⁻⁹ /h
AS-i ID Code 0xB
AS-i IO Code 0x0
AS-i Profile S-0.B.F.E
Impact Resistance 30 g / 11 ms
AS-i ID Code 1 0xF
AS-i ID Code 2 0xE
AS-i Version V 2.1
Mission Time 20 Year(s)
Direction of Movement Active to the surface vertical
Cable Length 2 m
Gross Weight 76 g
Housing Material Cam elyaf takviyeli termoplastik
Door Hinge Left
Protection Class II
Pollution Degree 3
Note (PFH Value) up to max. 500,000 switching cycles/year
Sensor Length 13 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 55 Hz, amplitude 1 mm
Number of Cable Wires 2
AS-i Specification Safety Slave
Actuation Element Magnet
IP Protection Class IP67
Max. Response Time 100 ms
Ambient Temperature -25 ... +60 °C
Performance Level e
Operating Principle Magnetic drive
Sensor Height 26 mm
Recommendation (Actuator) BPS 260-1 BPS 260-2
AS-i Input Channel 1 Veri bitleri DI 0 / DI 1 = dinamik kod iletimi
AS-i Input Channel 2 Veri bitleri DI 2 / DI 3 = dinamik kod iletimi
Terminal Connection Connection cable, 2 pole
Suitable SIL Applications 3
Cable Sheath Material PVC
AS-i Max. Current Consumption 50 mA
AS-i Output DO 0...DO 3 No function
Mechanical Mounting Conditions Semi-recessed
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Note (Repeat Accuracy R) Repeat accuracy R ≤ 0,1 x S ao
AS-i Input Module Address 0
Overvoltage Category III
Rated Operating Voltage 18 ... 31.6 VDC (Reverse polarity protection)
Note (AS-i Parameter Bits) Set the parameter outputs to "1111" (0xF). FID: peripheral error
Guaranteed Opening Distance (ON) Sao 5 mm
Note (Switching Distance Sn) Axial misalignment: horizontal and vertical misalignment between the safety sensor and the actuator is tolerated. The possible misalignment depends on the distance between the active surfaces of the sensor and the actuator. The sensor remains active within the tolerance range.
AS-i Parameter Bits P0...P3 No function
Impulse Withstand Voltage (Uimp) 0.8 kV
Guaranteed Opening Distance (OFF) Sar 15 mm
Storage/Transport Temperature -25 ... +70 °C
Integrated System Diagnostics Status Yes
Rated Insulation Voltage (Uᵢ) 32 VDC
Note (AS-i Input Module Address) Adres 0'a front set; AS-interface bus master or el type programlama device with changeable
Note (LED Switching Condition Indication) (1) LED green: Supply voltage (2) red LED: AS-i communication error / Slave address = 0
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.