Order No
101194921
Article Code
101194921
Certificates
cULus ASi-SaW
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Sensörleri
BNS 36 AS-L
Product Description
- • IP Rating: IP67 | Voltage: 18 ... 31.6 VDC | Weight: 95 g | Cable: 2 m | Certification: cULus ASi-SaW | PL e
Standards
- • EN ISO 13849-1 EN IEC 61508
Product Features
- • 2 m Pre-wired cable, 2-pole_x000D_
- • Safety sensor_x000D_
- • Termoplastik gövde_x000D_
- • Mekanik aşınma yok_x000D_
- • 88 mm x 25 mm x 13 mm_x000D_
- • Entegre AS-Interface_x000D_
- • Gizli montaj mümkün_x000D_
- • Uzun ömürlü_x000D_
- • Yanal hizasızlığa karşı duyarsız_x000D_
- • Kirlenmeye karşı duyarsız_x000D_
- • AS-Interface LED and status display
Technical Specifications
PIN 1
Brown (AS interface +)
PIN 2
n.c.
PIN 3
Blue (AS interface −)
PIN 4
n.c.
Coding
Yes
Category
4
Cable Type
LSYY
Wire Cross-Section
23 AWG
PFH Value
1.24 x 10⁻⁸ /h
AS-i ID Code
0xB
AS-i IO Code
0x0
AS-i Profile
S-0.B.F.E
Impact Resistance
30 g / 11 ms
AS-i ID Code 1
0xF
AS-i ID Code 2
0xE
AS-i Version
V 2.1
Mission Time
20 Year(s)
Direction of Movement
Active to the surface vertical
Cable Length
2 m
Gross Weight
95 g
Housing Material
Cam elyaf takviyeli termoplastik
Door Hinge
Left
Pollution Degree
3
Note (PFH Value)
up to max. 500,000 switching cycles/year
Sensor Length
13 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 55 Hz, amplitude 1 mm
Number of Cable Wires
2
AS-i Specification
Safety Slave
Actuation Element
Magnet
IP Protection Class
IP67
Max. Response Time
100 ms
Ambient Temperature
-25 ... +60 °C
Performance Level
e
Sensor Width
88 mm
Operating Principle
Magnetic drive
Sensor Height
25 mm
Recommendation (Actuator)
BPS 36-2
AS-i Input Channel 1
Veri bitleri DI 0 / DI 1 = dinamik kod iletimi
AS-i Input Channel 2
Veri bitleri DI 2 / DI 3 = dinamik kod iletimi
Terminal Connection
Connection cable, 2 pole
Suitable SIL Applications
3
Cable Sheath Material
PVC
AS-i Max. Current Consumption
50 mA
AS-i Output DO 0...DO 3
No function
Mechanical Mounting Conditions
Semi-recessed
Note (Switching Distance)
All switching distances EN IEC 60947-5-3'e is according to
Note (Repeat Accuracy R)
Repeat accuracy R ≤ 0,1 x S ao
AS-i Input Module Address
0
Overvoltage Category
III
Rated Operating Voltage
18 ... 31.6 VDC (Reverse polarity protection)
Note (AS-i Parameter Bits)
Set the parameter outputs to "1111" (0xF)
Guaranteed Opening Distance (ON) Sao
7 mm
Note (Switching Distance Sn)
Eksenel misalignment, safety sensor and of the actuator yatay and dikey to misalignment tolerans is shown. Possible that is misalignment, sensor and of the actuator active surfaces between mesafeye depends on. Sensor tolerans in the range of active remains.
AS-i Parameter Bits P0...P3
No function
Impulse Withstand Voltage (Uimp)
0.8 kV
Guaranteed Opening Distance (OFF) Sar
17 mm
Storage/Transport Temperature
-25 ... +70 °C
Integrated System Diagnostics Status
Yes
Coding Level (EN ISO 14119)
Low
Rated Insulation Voltage (Uᵢ)
32 VDC
Note (AS-i Input Module Address)
Adres 0'a front set; AS-interface bus master or el type programlama device with changeable
Note (LED Switching Condition Indication)
(1) LED green-red (AS-i Duo LED): Supply voltage / Communication error / Slave address = 0 (2) LED yellow: Enabling status