EX-AZ 3350-12ZUEK-U270-3D
Order No 101185216
Article Code 101185216
Certificates ATEX (Konformitätserklärung)
Schmersal Emniyetli Anahtarlama ve Denetleme Ayrı Aktüatörlü Emniyet Şalterleri

EX-AZ 3350-12ZUEK-U270-3D

Product Description

  • • IP Rating: IP67 | Weight: 195 g

Standards

  • • EN ISO 13849-1

Product Features

  • • Actuating head rotated by 270°_x000D_
  • • Ex-Zone 22_x000D_
  • • Metal gövde_x000D_
  • • 40,5 mm x 114 mm x 38 mm_x000D_
  • • Latching handle_x000D_
  • • 1 Kablo girişi M20 x 1,5_x000D_
  • • Centring device available_x000D_
  • • Düşük gerilim ve akımlarda yüksek kontak güvenilirliği_x000D_
  • • SZ 415 lockout tag to prevent unintended closing

Technical Specifications

Note All belirtimler iletken end included.
Mission Time 20 Year(s)
Gross Weight 195 g
Housing Material Hafif alloy pressurized cast
Door Hinge Right
Contact Material Silver
Min. Cable Cross-Section 0.75 mm²
Sensor Length 38 mm
Scope of Delivery Actuator additionally order must be. Ex-certified screwed cable gland
Max. Cable Cross-Section 2.5 mm²
IP Protection Class IP67
Ambient Temperature -10 ... +60 °C
Sensor Width 40.5 mm
Thermal Test Current 0.4166666666678793
Switching Element NA contact, NK contact
Switching Principle Slow hareket
Mechanical Life (min.) 1,000,000 Cycles
Note (B10D NA Contact) %10 Ie and ohmic load for
Sensor Height 114 mm
Actuator Rotation 270 °
B10D NA Contact Value 1,000,000 Cycles
B10D NC Contact Value 2,000,000 Cycles
Positive Opening Distance 10.7 mm
Terminal Connection Threaded terminal block M20 x 1,5
Max. Actuation Speed 1 m/s
Explosion Protection Definition D II 3D Ex tc IIIC T90°C Dc X
Housing Coating Material Painted
Min. Cable Gland Cross-Section 6 mm
Number of Safety Contacts 2
Max. Cable Gland Cross-Section 12 mm
Explosion Protection Zones 22
Explosion Protection Category 3D
Utilization Category AC-15 0.16666666666787933
Utilization Category DC-13 0.16666666666787933
Min. Positive Opening Force 5 N
Number of Auxiliary Contacts 1
Note (Positive Opening Force) per NC
Impulse Withstand Voltage (Uimp) 4 kV
Explosion Protection Regulations EN IEC 60079-0 EN 60079-31
Rated Insulation Voltage (Uᵢ) 250 VAC
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.