Order No
103002620
Article Code
103002620
Certificates
CCC-EX ATEX (Konformitätserklärung)
Schmersal
Emniyetli Anahtarlama ve Denetleme
Solenoid Kilitler
EX-AZM 161CC-12/12RKA-024-3D
Product Description
- • IP Rating: IP67 | Dimensions: 278mm×122mm | Weight: 470 g | PL d
Standards
- • EN ISO 13849-1
Product Features
- • Cage clamps_x000D_
- • Ex-Zone 22_x000D_
- • 130 mm x 90 mm x 30 mm_x000D_
- • Clamping force 2000N_x000D_
- • 6 kontak_x000D_
- • Manuel açma_x000D_
- • Hatalı kilitlemeye karşı korumalı kilit_x000D_
- • cable entries 4 M 16 x 1.5
Technical Specifications
Note
The tightening sequence of the cover screws must be observed. This can be found in the attached drawing in the “Pictures” tab.
Mounting
Vidalar
Length
40 mm
Category
3
Width
278 mm
Height
122 mm
Application Note
Slide-mounted guard cover removable cover hinged guard cover
Mission Time
20 Year(s)
Please Note
Single channel mekanizmaya tehlikeli hasar for fault of excluding kabul edilebilir and to manipulation counter sufficient protection garanti that is done cases...
Gross Weight
470 g
Housing Material
Plastik, cam elyaf takviyeli termoplastik, automatically fading
Contact Material
Silver
Screw Head Type
Flat headed screw
Locking Force
30 N
Min. Cable Cross-Section
1 x 0.75 mm²
Note (Relative Humidity)
Non-condensing, non-icing
Scope of Delivery
Actuator and guard housing teslimat in the scope of included not.
Max. Cable Cross-Section
1 x 1.5 mm²
Manual Lock Release
Yes
IP Protection Class
IP67
Ambient Temperature
-10 ... +50 °C
Performance Level
d
Thermal Test Current
0.25
Operating Principle
Elektromekanik
Switching Element
NA contact, NK contact
Switching Principle
Slow hareket, pozitif opening NK contact
Max. Impact Energy
7 J
Mechanical Life (min.)
1,000,000 Cycles
B10D NA Contact Value
1,000,000 Cycles
B10D NC Contact Value
2,000,000 Cycles
Force to Lock
Yes
Positive Opening Distance
10 mm
Fixing Screw Type
3x M6
Terminal Connection
Cage clamps
Max. Actuation Speed
1 m/s
Explosion Protection Definition
D II 3D Ex tc IIIC T80°C Dc X
Max. Test Pulse Duration
5 ms
Max. Holding Force Fmax
2,600 N
Min. Cable Gland Cross-Section
5 mm
Rated Control Voltage
24 VDC
Note (Manual Lock Release)
For maintenance, installation, etc.
Number of Safety Contacts
4
Cable Gland Tightening Torque
3 Nm
Max. Cable Gland Cross-Section
10 mm
Explosion Protection Zones
22
Explosion Protection Category
3D
Number of Actuation Directions
3
Current Utilization Cat. DC-13
2.5 A
Utilization Category DC-13
2.5 A
Min. Test Pulse Interval
50 ms
Number of Auxiliary Contacts
2
Max. Switching Frequency
1,000 /h
Magnet Release Time
1
Voltage Utilization Cat. DC-13
24 VDC
Impulse Withstand Voltage (Uimp)
4 kV
Explosion Protection Regulations
EN IEC 60079-0 EN 60079-31
Holding Force FZh (EN ISO 14119)
2,000 N
Max. Electrical Power Consumption
10 W
Min. Positive Opening Force/Contact
10 N
Rated Insulation Voltage (Uᵢ)
250 VAC
Play in Direction of Actuation
5.5 mm
Required Rated Short-Circuit Current
1,000 A
Housing Cover Screw Tightening Torque
0.6 Nm
Max. Impact Energy (Protective Housing)
7 J