Order No
101185026
Article Code
101185026
Certificates
ATEX (Konformitätserklärung)
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Sensörleri
EX-BNS 303-12Z-2187-3G/D
Product Description
- • IP Rating: IP67 | Weight: 95 g | Cable: 1 m | Contacts: 2 NC, 1 NO
Standards
- • EN ISO 13849-1
Product Features
- • ATEX Zon 2 ve 22 için patlama koruması_x000D_
- • Termoplastik gövde_x000D_
- • Ø M30_x000D_
- • With coding_x000D_
- • Yanal hizasızlığa karşı duyarsız_x000D_
- • Suitable for food processing industry only in combination with BPS 303 SS_x000D_
- • Mekanik aşınma yok
Technical Specifications
Coding
Yes
General Note
Contact sembolleri guard of the device closed condition for is shown. LED'li/LED'siz of the versions contact configuration is the same.
Active Area
front taraf
Wire Cross-Section
23 AWG
Impact Resistance
30 g / 11 ms
Mission Time
20 Year(s)
Direction of Movement
Active to the surface vertical
Cable Length
1 m
Nut Material
Termoplastik
Gross Weight
95 g
Housing Material
Cam elyaf takviyeli termoplastik
Manufacturer Declaration
ATEX Zone 2 and 22
Sensor ISO Thread
M30
Sensor Length
44 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 55 Hz, amplitude 1 mm
Number of Cable Wires
6
Actuation Element
Magnet
Switch Width
36 BK
IP Protection Class
IP67
Short-Circuit Detection
Yes
Ambient Temperature
-25 ... +70 °C
Switching Element
1 NA contact, 2 NK contact
Switching Principle
Reed contacts, non-contact prensip
Max. Impact Energy
4 J
Housing Design Form
Threaded cylinder
Recommendation (Actuator)
BPS 300 BPS 303 BPS 303 SS coded
Cross-Circuit Detection
Yes
Terminal Connection
Cable
Explosion Protection Definition
D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X
Max. Nut Tightening Torque
3 Nm
B10D NC/NA Contact Value
25,000,000 Cycles
Number of Safety Contacts
2
Cable Sheath Material
PVC
Max. Switching Current
0.4 A
Explosion Protection Zones
2 22
Explosion Protection Category
3G 3D
Max. Switching Voltage
100 VDC
Mechanical Mounting Conditions
Semi-recessed
Note (Switching Distance)
All switching distances EN IEC 60947-5-3'e is according to
Max. Switching Capacity
10 W
Guaranteed Opening Distance (ON) Sao
5 mm
Guaranteed Opening Distance (OFF) Sar
15 mm
Explosion Protection Regulations
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31
Storage/Transport Temperature
-25 ... +70 °C
Recommended Safety Switch
SRB-E-301ST SRB-E-201LC
Max. Switching Frequency (Approx.)
5 Hz
Mounting Material Scope of Delivery
2x nuts M30 x 1.5
Number of NO (Normally Open) Contacts
1
Number of NC (Normally Closed) Contacts
2