EX-BNS 303-12Z-2187-3G/D
Order No 101185026
Article Code 101185026
Certificates ATEX (Konformitätserklärung)
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Sensörleri

EX-BNS 303-12Z-2187-3G/D

Product Description

  • • IP Rating: IP67 | Weight: 95 g | Cable: 1 m | Contacts: 2 NC, 1 NO

Standards

  • • EN ISO 13849-1

Product Features

  • • ATEX Zon 2 ve 22 için patlama koruması_x000D_
  • • Termoplastik gövde_x000D_
  • • Ø M30_x000D_
  • • With coding_x000D_
  • • Yanal hizasızlığa karşı duyarsız_x000D_
  • • Suitable for food processing industry only in combination with BPS 303 SS_x000D_
  • • Mekanik aşınma yok

Technical Specifications

Coding Yes
General Note Contact sembolleri guard of the device closed condition for is shown. LED'li/LED'siz of the versions contact configuration is the same.
Active Area front taraf
Wire Cross-Section 23 AWG
Impact Resistance 30 g / 11 ms
Mission Time 20 Year(s)
Direction of Movement Active to the surface vertical
Cable Length 1 m
Nut Material Termoplastik
Gross Weight 95 g
Housing Material Cam elyaf takviyeli termoplastik
Manufacturer Declaration ATEX Zone 2 and 22
Sensor ISO Thread M30
Sensor Length 44 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 55 Hz, amplitude 1 mm
Number of Cable Wires 6
Actuation Element Magnet
Switch Width 36 BK
IP Protection Class IP67
Short-Circuit Detection Yes
Ambient Temperature -25 ... +70 °C
Switching Element 1 NA contact, 2 NK contact
Switching Principle Reed contacts, non-contact prensip
Max. Impact Energy 4 J
Housing Design Form Threaded cylinder
Recommendation (Actuator) BPS 300 BPS 303 BPS 303 SS coded
Cross-Circuit Detection Yes
Terminal Connection Cable
Explosion Protection Definition D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X
Max. Nut Tightening Torque 3 Nm
B10D NC/NA Contact Value 25,000,000 Cycles
Number of Safety Contacts 2
Cable Sheath Material PVC
Max. Switching Current 0.4 A
Explosion Protection Zones 2 22
Explosion Protection Category 3G 3D
Max. Switching Voltage 100 VDC
Mechanical Mounting Conditions Semi-recessed
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Max. Switching Capacity 10 W
Guaranteed Opening Distance (ON) Sao 5 mm
Guaranteed Opening Distance (OFF) Sar 15 mm
Explosion Protection Regulations EN IEC 60079-0 EN IEC 60079-15 EN 60079-31
Storage/Transport Temperature -25 ... +70 °C
Recommended Safety Switch SRB-E-301ST SRB-E-201LC
Max. Switching Frequency (Approx.) 5 Hz
Mounting Material Scope of Delivery 2x nuts M30 x 1.5
Number of NO (Normally Open) Contacts 1
Number of NC (Normally Closed) Contacts 2
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.