EX-BNS 303-12Z-2187-3G/D 5,0M
Order No 101187774
Article Code 101187774
Certificates ATEX (Konformitätserklärung)
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Sensörleri

EX-BNS 303-12Z-2187-3G/D 5,0M

Product Description

  • • IP Rating: IP67 | Weight: 226 g | Cable: 5 m | Contacts: 2 NC, 1 NO

Standards

  • • EN ISO 13849-1

Product Features

  • • ATEX Zon 2 ve 22 için patlama koruması_x000D_
  • • Termoplastik gövde_x000D_
  • • Ø M30_x000D_
  • • With coding_x000D_
  • • Yanal hizasızlığa karşı duyarsız_x000D_
  • • Suitable for food processing industry only in combination with BPS 303 SS_x000D_
  • • Mekanik aşınma yok

Technical Specifications

Coding Yes
General Note Contact sembolleri, guard of the device closed condition for is shown. LED'li or LED'siz of the versions contact configuration is the same.
Active Area front taraf
Wire Cross-Section 23 AWG
Impact Resistance 30 g / 11 ms
Mission Time 20 Year(s)
Direction of Movement Active to the surface vertical
Cable Length 5 m
Nut Material Termoplastik
Gross Weight 226 g
Housing Material Cam elyaf takviyeli termoplastik
Manufacturer Declaration ATEX Zone 2 and 22
Sensor ISO Thread M30
Sensor Length 44 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 55 Hz, amplitude 1 mm
Number of Cable Wires 6
Actuation Element Magnet
Switch Width 36 BK
IP Protection Class IP67
Short-Circuit Detection Yes
Ambient Temperature -25 ... +70 °C
Switching Element 1 NA contact, 2 NK contact
Switching Principle Reed contacts, non-contact prensip
Max. Impact Energy 4 J
Housing Design Form Threaded cylinder
Recommendation (Actuator) BPS 300 BPS 303 BPS 303 SS coded
Cross-Circuit Detection Yes
Terminal Connection Cable
Explosion Protection Definition D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X
Max. Nut Tightening Torque 3 Nm
B10D NC/NA Contact Value 25,000,000 Cycles
Number of Safety Contacts 2
Cable Sheath Material PVC
Max. Switching Current 0.4 A
Explosion Protection Zones 2 22
Explosion Protection Category 3G 3D
Max. Switching Voltage 100 VDC
Mechanical Mounting Conditions Semi-recessed
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Max. Switching Capacity 10 W
Guaranteed Opening Distance (ON) Sao 5 mm
Guaranteed Opening Distance (OFF) Sar 15 mm
Explosion Protection Regulations EN IEC 60079-0 EN IEC 60079-15 EN 60079-31
Storage/Transport Temperature -25 ... +70 °C
Recommended Safety Switch SRB-E-301ST SRB-E-201LC
Max. Switching Frequency (Approx.) 5 Hz
Mounting Material Scope of Delivery 2x nuts M30 x 1.5
Number of NO (Normally Open) Contacts 1
Number of NC (Normally Closed) Contacts 2
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.