Order No
101189236
Article Code
101189236
Certificates
ATEX (Konformitätserklärung)
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Sensörleri
EX-BNS 303-12ZG-2187-3G/D 5,0M
Product Description
- • IP Rating: IP67 | Weight: 235 g | Cable: 5 m | Contacts: 2 NC, 1 NO
Standards
- • EN ISO 13849-1
Product Features
- • LED version_x000D_
- • ATEX Zon 2 ve 22 için patlama koruması_x000D_
- • Termoplastik gövde_x000D_
- • Ø M30_x000D_
- • With coding_x000D_
- • Yanal hizasızlığa karşı duyarsız_x000D_
- • Suitable for food processing industry only in combination with BPS 303 SS_x000D_
- • Mekanik aşınma yok
Technical Specifications
Coding
Yes
General Note
Contact sembolleri, guard of the device closed condition for is shown. LED'li or LED'siz of the versions contact configuration is the same.
Active Area
front taraf
Wire Cross-Section
23 AWG
Impact Resistance
30 g / 11 ms
Mission Time
20 Year(s)
Direction of Movement
Active to the surface vertical
Cable Length
5 m
Nut Material
Termoplastik
Gross Weight
235 g
Housing Material
Cam elyaf takviyeli termoplastik
Manufacturer Declaration
ATEX Zone 2 and 22
Sensor ISO Thread
M30
Sensor Length
44 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 55 Hz, amplitude 1 mm
Number of Cable Wires
6
Actuation Element
Magnet
Switch Width
36 BK
IP Protection Class
IP67
Short-Circuit Detection
Yes
Ambient Temperature
-25 ... +70 °C
Switching Element
1 NA contact, 2 NK contact
Switching Principle
Reed contacts, non-contact prensip
Max. Impact Energy
4 J
Housing Design Form
Threaded cylinder
Recommendation (Actuator)
BPS 300 BPS 303 BPS 303 SS coded
Cross-Circuit Detection
Yes
Terminal Connection
Cable
Explosion Protection Definition
D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X
Max. Nut Tightening Torque
3 Nm
B10D NC/NA Contact Value
25,000,000 Cycles
Number of Safety Contacts
2
Cable Sheath Material
PVC
Max. Switching Current
0.01 A
Explosion Protection Zones
2 22
Explosion Protection Category
3G 3D
Max. Switching Voltage
24 VDC
Mechanical Mounting Conditions
Semi-recessed
Note (Switching Distance)
All switching distances EN IEC 60947-5-3'e is according to
Max. Switching Capacity
0.24 W
Guaranteed Opening Distance (ON) Sao
5 mm
Guaranteed Opening Distance (OFF) Sar
15 mm
Explosion Protection Regulations
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31
Storage/Transport Temperature
-25 ... +70 °C
Recommended Safety Switch
SRB-E-301ST SRB-E-201LC
Integrated System Diagnostics (General)
Yes
Max. Switching Frequency (Approx.)
5 Hz
Mounting Material Scope of Delivery
2x nuts M30 x 1.5
Number of NO (Normally Open) Contacts
1
Number of NC (Normally Closed) Contacts
2
Note (Integrated System Diagnostics Status)
LED lights up when the guard door is open.