EX-BNS 33-12ZG-2187-3G/D 5,0M
Order No 101189299
Article Code 101189299
Certificates ATEX (Konformitätserklärung)
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Sensörleri

EX-BNS 33-12ZG-2187-3G/D 5,0M

Product Description

  • • IP Rating: IP67 | Weight: 225 g | Cable: 5 m | Contacts: 2 NC, 1 NO

Standards

  • • EN ISO 13849-1

Product Features

  • • Individual contact outlet_x000D_
  • • ATEX Zon 2 ve 22 için patlama koruması_x000D_
  • • Termoplastik gövde_x000D_
  • • 88 mm x 25 mm x 13 mm_x000D_
  • • Gizli montaj mümkün_x000D_
  • • Yanal hizasızlığa karşı duyarsız_x000D_
  • • Mekanik aşınma yok

Technical Specifications

Coding Yes
General Note Contact sembolleri guard of the device closed konumu for is shown.
Active Area Yanal
Wire Cross-Section 23 AWG
Impact Resistance 30 g / 11 ms
Mission Time 20 Year(s)
Direction of Movement Active to the surface vertical
Cable Length 5 m
Gross Weight 225 g
Housing Material Cam elyaf takviyeli termoplastik
Manufacturer Declaration ATEX Zone 2 and 22
Sensor Length 13 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 55 Hz, amplitude 1 mm
Number of Cable Wires 6
Actuation Element Magnet
IP Protection Class IP67
Short-Circuit Detection Yes
Sensor Width 88 mm
Switching Element 1 NA contact, 2 NK contact
Switching Principle Reed contacts, non-contact prensip
Max. Impact Energy 1 J
Housing Design Form Blok
Sensor Height 25 mm
Recommendation (Actuator) EX-BPS 33-3G/D
Cross-Circuit Detection Yes
B10D NC Contact Value 25,000,000 Cycles
Terminal Connection Cable
Explosion Protection Definition D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X
B10D NC/NA Contact Value 25,000,000 Cycles
Cable Sheath Material PVC
Max. Switching Current 0.01 A
Explosion Protection Zones 2 22
Explosion Protection Category 3G 3D
Max. Switching Voltage 24 VDC
Mechanical Mounting Conditions Embedded not
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Note (Repeat Accuracy R) Repeat accuracy R ≤ 0,1 x S ao
Max. Switching Capacity 0.24 W
Guaranteed Opening Distance (ON) Sao 5 mm
Guaranteed Opening Distance (OFF) Sar 15 mm
Explosion Protection Regulations EN IEC 60079-0 EN IEC 60079-15 EN 60079-31
Integrated System Diagnostics Status Yes
Precondition Evaluation Unit Yes
Max. Switching Frequency (Approx.) 5 Hz
Number of NO (Normally Open) Contacts 1
Number of NC (Normally Closed) Contacts 2
Note (Integrated System Diagnostics Status) LED lights up when the guard door is open.
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3