Order No
101189299
Article Code
101189299
Certificates
ATEX (Konformitätserklärung)
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Sensörleri
EX-BNS 33-12ZG-2187-3G/D 5,0M
Product Description
- • IP Rating: IP67 | Weight: 225 g | Cable: 5 m | Contacts: 2 NC, 1 NO
Standards
- • EN ISO 13849-1
Product Features
- • Individual contact outlet_x000D_
- • ATEX Zon 2 ve 22 için patlama koruması_x000D_
- • Termoplastik gövde_x000D_
- • 88 mm x 25 mm x 13 mm_x000D_
- • Gizli montaj mümkün_x000D_
- • Yanal hizasızlığa karşı duyarsız_x000D_
- • Mekanik aşınma yok
Technical Specifications
Coding
Yes
General Note
Contact sembolleri guard of the device closed konumu for is shown.
Active Area
Yanal
Wire Cross-Section
23 AWG
Impact Resistance
30 g / 11 ms
Mission Time
20 Year(s)
Direction of Movement
Active to the surface vertical
Cable Length
5 m
Gross Weight
225 g
Housing Material
Cam elyaf takviyeli termoplastik
Manufacturer Declaration
ATEX Zone 2 and 22
Sensor Length
13 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 55 Hz, amplitude 1 mm
Number of Cable Wires
6
Actuation Element
Magnet
IP Protection Class
IP67
Short-Circuit Detection
Yes
Sensor Width
88 mm
Switching Element
1 NA contact, 2 NK contact
Switching Principle
Reed contacts, non-contact prensip
Max. Impact Energy
1 J
Housing Design Form
Blok
Sensor Height
25 mm
Recommendation (Actuator)
EX-BPS 33-3G/D
Cross-Circuit Detection
Yes
B10D NC Contact Value
25,000,000 Cycles
Terminal Connection
Cable
Explosion Protection Definition
D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X
B10D NC/NA Contact Value
25,000,000 Cycles
Cable Sheath Material
PVC
Max. Switching Current
0.01 A
Explosion Protection Zones
2 22
Explosion Protection Category
3G 3D
Max. Switching Voltage
24 VDC
Mechanical Mounting Conditions
Embedded not
Note (Switching Distance)
All switching distances EN IEC 60947-5-3'e is according to
Note (Repeat Accuracy R)
Repeat accuracy R ≤ 0,1 x S ao
Max. Switching Capacity
0.24 W
Guaranteed Opening Distance (ON) Sao
5 mm
Guaranteed Opening Distance (OFF) Sar
15 mm
Explosion Protection Regulations
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31
Integrated System Diagnostics Status
Yes
Precondition Evaluation Unit
Yes
Max. Switching Frequency (Approx.)
5 Hz
Number of NO (Normally Open) Contacts
1
Number of NC (Normally Closed) Contacts
2
Note (Integrated System Diagnostics Status)
LED lights up when the guard door is open.