Order No
103015297
Article Code
103015297
Certificates
ATEX (Konformitätserklärung)
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Sensörleri
EX-BNS 40S-12ZG 20,0M
Product Description
- • IP Rating: IP65/IP67 | Weight: 1,200 g | Cable: 20 m | Contacts: 2 NC, 1 NO
Standards
- • EN ISO 13849-1
Product Features
- • ATEX Zon 2 ve 22 için patlama koruması_x000D_
- • Stainless steel enclosure_x000D_
- • 88 mm x 27 mm x 14,5 mm_x000D_
- • Gizli montaj mümkün_x000D_
- • Yanal hizasızlığa karşı duyarsız_x000D_
- • Mekanik aşınma yok_x000D_
- • Suitable for food processing industry_x000D_
- • Cable connection suitable for the food industry
Technical Specifications
Coding
Yes
General Note
Contact sembolleri guard of the device closed condition for is shown. LED'li/LED'siz of the versions contact configuration is the same.
Active Area
Yanal
Cable Type
LiYY
Wire Cross-Section
23 AWG
Impact Resistance
30 g / 11 ms
Mission Time
20 Year(s)
Direction of Movement
Active to the surface vertical
Cable Length
20 m
Gross Weight
1,200 g
Housing Material
Stainless steel (V4A)
Manufacturer Declaration
ATEX Zone 2 and 22
Sensor Length
14.5 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 55 Hz, amplitude 1 mm
Number of Cable Wires
6
Actuation Element
Magnet
IP Protection Class
IP65 IP67
Short-Circuit Detection
Yes
Ambient Temperature
-20 ... +60 °C
Sensor Width
88 mm
Switching Element
1 NA contact, 2 NK contact
Switching Principle
Reed contacts, non-contact prensip
Max. Impact Energy
7 J
Housing Design Form
Blok
Sensor Height
27 mm
Recommendation (Actuator)
BPS 40S-2 BPS 40S-1-C BPS 40S-2-C
Cross-Circuit Detection
Yes
Terminal Connection
Cable
Explosion Protection Definition
D II 3G Ex nA nC IIC T6 Gc D II 3D Ex tc IIIC T80°C Dc X
Connection Diagram Note
S21-S22 contact safety devresine integrated must be.
B10D NC/NA Contact Value
25,000,000 Cycles
Cable Sheath Material
PVC
Max. Switching Current
0.01 A
Explosion Protection Zones
2 22
Explosion Protection Category
3G 3D
Max. Switching Voltage
24 VDC
Mechanical Mounting Conditions
Embedded not
Note (Switching Distance)
All switching distances EN IEC 60947-5-3'e is according to
Hidden Threaded Holes at the Rear
Yes
Max. Switching Capacity
0.24 W
Guaranteed Opening Distance (ON) Sao
8 mm
Guaranteed Opening Distance (OFF) Sar
18 mm
Explosion Protection Regulations
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31
Storage/Transport Temperature
-25 ... +80 °C
Recommended Safety Switch
SRB-E-301ST SRB-E-201LC
Integrated System Diagnostics (General)
Yes
Precondition Evaluation Unit
Yes
Max. Switching Frequency (Approx.)
5 Hz
Required Rated Short-Circuit Current
100 A
Number of NO (Normally Open) Contacts
1
Number of NC (Normally Closed) Contacts
2
Note (Integrated System Diagnostics Status)
LED, guard when closed yanar.