EX-RSS16-D-10M-3G/D
Order No 103027921
Article Code 103027921
Certificates TÜV ATEX (Konformitätserklärung)
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Sensörleri

EX-RSS16-D-10M-3G/D

Product Description

  • • IP Rating: IP65/IP67 | Voltage: 24 VDC | Cable: 10 m | PL e

Standards

  • • EN ISO 13849-1 EN IEC 61508

Product Features

  • • ATEX Zon 2 ve 22 için patlama koruması_x000D_
  • • Termoplastik gövde_x000D_
  • • İhtiyaca dayalı müdahale koruması için RFID teknolojisi_x000D_
  • • 3 different directions of actuation

Technical Specifications

Mounting 2 x M5, Cylinder headed screw
Coding Universal coding
Category 4
Active Area lateral front taraf cover-side
PFD Value 1.50 x 10⁻⁵
PFH Value 6.30 x 10⁻¹¹ /h
Number of LEDs 2
Impact Resistance 30 g / 11 ms
Mission Time 20 Year(s)
Max. Hysteresis 2 mm
Cable Length 10 m
Series Connection Yes
Gross Weight g
Housing Material Plastik, cam elyaf takviyeli termoplastik, automatically fading
Pollution Degree 3
Max. Relative Humidity 0.93
Note (Relative Humidity) Non-condensing, non-icing
Radiated Interference IEC 61000-6-4
Sensor Length 91 mm
Scope of Delivery Actuator additionally order must be.
Max. Risk Time 200 ms
Sensor Topology Series connection for sensor
Operating Current 50 mA
IP Protection Class IP65 IP67
Short-Circuit Detection Yes
Max. Response Time 100 ms
Ambient Temperature -20 ... +60 °C
Performance Level e
Sensor Width 52 mm
Operating Voltage 24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle RFID
Actuation Panels front taraf rear from head
Cascadable Yes
Housing Design Form Blok
Sensor Height 30 mm
Recommendation (Actuator) RST16-1
Repeat Accuracy R 0.5 mm
Note (Series Connection) Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Diagnostic Output Yes
Cross-Circuit Detection Yes
Max. Leakage Current (Ir) 0.5 mA
Min. Operating Current 0.5 mA
Explosion Protection Definition D II 3D Ex tc IIIC T90°C Dc X
Suitable SIL Applications 3
Safety Functions Yes
Max. Installation Altitude 2,000 m
Max. Ready Time 2,000 ms
Explosion Protection Category 3G 3D
Manufacturer Declaration Region 2 22
Current Utilization Cat. DC-12 0.05 A
Current Utilization Cat. DC-13 0.05 A
Utilization Category DC-12 24 VDC / 0.05 A
Mechanical Mounting Conditions Embedded not
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Typical Switching Distance 15 mm
Overvoltage Category III
Rated Operating Voltage 24 VDC
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
Guaranteed Opening Distance (ON) Sao 12 mm
Max. Voltage Drop (Ud) 2 V
Impulse Withstand Voltage (Uimp) 0.8 kV
Guaranteed Opening Distance (OFF) Sar 30 mm
Control Elements Design p-tipi
Explosion Protection Regulations EN IEC 60079-0 EN 60079-7 EN 60079-31
Fixing Screw Tightening Torque 2 Nm
Storage/Transport Temperature -25 ... +85 °C
Integrated System Diagnostics Status Yes
Coding Level (EN ISO 14119) Low
Note (Sensor Chain Length) Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch PROTECT PSC1 SRB-E-301ST SRB-E-201LC SRB101EXi SRB200EXi
Rated Insulation Voltage (Uᵢ) 32 VDC
Max. Switching Frequency (Approx.) 1 Hz
Required Rated Short-Circuit Current 100 A
Number of Safe Digital Outputs 2
Safety Inputs Current Consumption 5 mA
Typical Idle Operating Current (I₀) 100 mA
Max. Output Current (Safe Output) 0.041666666667879326
Note (LED Switching Condition Indication) Very renkli LED: Green, Red Yellow LED: Operation status Green LED: Supply voltage Red LED: Fault
Number of Semiconductor Outputs with Signal Function 1
Rated Operating Current (Safety Outputs) 1,000 mA
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3