Order No
103027921
Article Code
103027921
Certificates
TÜV ATEX (Konformitätserklärung)
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Sensörleri
EX-RSS16-D-10M-3G/D
Product Description
- • IP Rating: IP65/IP67 | Voltage: 24 VDC | Cable: 10 m | PL e
Standards
- • EN ISO 13849-1 EN IEC 61508
Product Features
- • ATEX Zon 2 ve 22 için patlama koruması_x000D_
- • Termoplastik gövde_x000D_
- • İhtiyaca dayalı müdahale koruması için RFID teknolojisi_x000D_
- • 3 different directions of actuation
Technical Specifications
Mounting
2 x M5, Cylinder headed screw
Coding
Universal coding
Category
4
Active Area
lateral front taraf cover-side
PFD Value
1.50 x 10⁻⁵
PFH Value
6.30 x 10⁻¹¹ /h
Number of LEDs
2
Impact Resistance
30 g / 11 ms
Mission Time
20 Year(s)
Max. Hysteresis
2 mm
Cable Length
10 m
Series Connection
Yes
Gross Weight
g
Housing Material
Plastik, cam elyaf takviyeli termoplastik, automatically fading
Pollution Degree
3
Max. Relative Humidity
0.93
Note (Relative Humidity)
Non-condensing, non-icing
Radiated Interference
IEC 61000-6-4
Sensor Length
91 mm
Scope of Delivery
Actuator additionally order must be.
Max. Risk Time
200 ms
Sensor Topology
Series connection for sensor
Operating Current
50 mA
IP Protection Class
IP65 IP67
Short-Circuit Detection
Yes
Max. Response Time
100 ms
Ambient Temperature
-20 ... +60 °C
Performance Level
e
Sensor Width
52 mm
Operating Voltage
24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle
RFID
Actuation Panels
front taraf rear from head
Cascadable
Yes
Housing Design Form
Blok
Sensor Height
30 mm
Recommendation (Actuator)
RST16-1
Repeat Accuracy R
0.5 mm
Note (Series Connection)
Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Diagnostic Output
Yes
Cross-Circuit Detection
Yes
Max. Leakage Current (Ir)
0.5 mA
Min. Operating Current
0.5 mA
Explosion Protection Definition
D II 3D Ex tc IIIC T90°C Dc X
Suitable SIL Applications
3
Safety Functions
Yes
Max. Installation Altitude
2,000 m
Max. Ready Time
2,000 ms
Explosion Protection Category
3G 3D
Manufacturer Declaration Region
2 22
Current Utilization Cat. DC-12
0.05 A
Current Utilization Cat. DC-13
0.05 A
Utilization Category DC-12
24 VDC / 0.05 A
Mechanical Mounting Conditions
Embedded not
Note (Switching Distance)
All switching distances EN IEC 60947-5-3'e is according to
Typical Switching Distance
15 mm
Overvoltage Category
III
Rated Operating Voltage
24 VDC
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
Guaranteed Opening Distance (ON) Sao
12 mm
Max. Voltage Drop (Ud)
2 V
Impulse Withstand Voltage (Uimp)
0.8 kV
Guaranteed Opening Distance (OFF) Sar
30 mm
Control Elements Design
p-tipi
Explosion Protection Regulations
EN IEC 60079-0 EN 60079-7 EN 60079-31
Fixing Screw Tightening Torque
2 Nm
Storage/Transport Temperature
-25 ... +85 °C
Integrated System Diagnostics Status
Yes
Coding Level (EN ISO 14119)
Low
Note (Sensor Chain Length)
Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch
PROTECT PSC1 SRB-E-301ST SRB-E-201LC SRB101EXi SRB200EXi
Rated Insulation Voltage (Uᵢ)
32 VDC
Max. Switching Frequency (Approx.)
1 Hz
Required Rated Short-Circuit Current
100 A
Number of Safe Digital Outputs
2
Safety Inputs Current Consumption
5 mA
Typical Idle Operating Current (I₀)
100 mA
Max. Output Current (Safe Output)
0.041666666667879326
Note (LED Switching Condition Indication)
Very renkli LED: Green, Red Yellow LED: Operation status Green LED: Supply voltage Red LED: Fault
Number of Semiconductor Outputs with Signal Function
1
Rated Operating Current (Safety Outputs)
1,000 mA