Order No
101198785
Article Code
101198785
Certificates
ATEX (Konformitätserklärung)
Schmersal
Emniyetli Anahtarlama ve Denetleme
Ayrı Aktüatörlü Emniyet Şalterleri
EX-SHGV/ESS21S2/210/11033-3G/D
Product Description
- • IP Rating: IP65 | Weight: 286 g
Standards
- • EN IEC 62061 EN ISO 14119 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 60204-1 EN IEC 60947-1
Product Features
- • Key-operated selector switch_x000D_
- • ATEX Zon 2 ve 22 için patlama koruması_x000D_
- • Metal gövde
Technical Specifications
Note
All belirtimler iletken end included.
Mounting
mounting flange
Range
40 x 50 mm
Lock Release
Rotary mandal opener
Versions
Anahtar - Selector anahtar - Front plate mounting
Fully Insulated
Yes
Impact Resistance
110 g / 4 ms
Latching
Yes
Mounting Diameter
22.3 mm
Number of Pistons
1
Front Ring Colour
Silver
Gross Weight
286 g
Housing Material
Plastik, cam elyaf takviyeli termoplastik, automatically fading
Contact Material
Silver
Front Ring Diameter
29.5 mm
Switch Number
210
Min. Cable Cross-Section
0.5 mm², rigid 0.5 mm², flexible
Screw Tightening Torque
0.6 Nm
Clip Tightening Torque
1 Nm
Max. Cable Cross-Section
2 x 1.5 mm² 2.5 mm², rigid 2.5 mm², flexible
Latching Position
right
IP Protection Class
IP65
Max. Bounce Time
5 ms
Ambient Temperature
+0 ... +70 °C
Thermal Test Current
0.4166666666678793
Front Ring Material
Aluminium
Switch Head Colour
Silver
Switching Element
NK contact, NA contact
Switching Principle
Slow hareket
Max. Impact Energy
4 J
Mechanical Life (min.)
100,000 Cycles
Cylinder Lock Colour
Silver
Sealing Type
Membrane Lip gaskets
Contact Element Colour
Siyah
Terminal Connection
Threaded terminal block M20 x 1,5
Vibration Resistant
Vibration direnci: 20 g / 10…200 Hz
Switch Withdrawn Position
Position I 90°
Suitable for Low Voltage
≥ 5 V / ≥ 3.2 mA
Explosion Protection Definition
D II 3D Ex tc IIIC T110°C Dc X D II 3G Ex ic IIC T5 Gc X
Number of Switch Positions
2
Cylinder Lock Material
Steel
Cylinder Lock Diameters
22 mm
Explosion Protection Zones
2 22
Utilization Category AC-15
0.3333333333321207
Utilization Category DC-13
0.20833333333212067
Mechanical Mounting Conditions
In the optional direction
Number of Auxiliary Contacts
1
Max. Switching Frequency
5 /h
IP Protection (Terminal Block)
IP20
Min. Front Panel Thickness
1 mm
Max. Front Panel Thickness
6 mm
Explosion Protection Regulations
EN IEC 60079-0 EN 60079-11 EN 60079-31
Length x Width x Height
Anahtar (and contact element) with height: 60 mm (119 mm)
Rated Insulation Voltage (Uᵢ)
400 V
Switch Compartments IP Protection Class
IP40