Order No
101217362
Article Code
101217362
Certificates
cULus ATEX (Konformitätserklärung)
Schmersal
Emniyetli Anahtarlama ve Denetleme
EX / ATEX Ürünleri
EX-T4VH 335-20ZH-3G/D
Product Description
- • IP Rating: IP67 | Weight: 360 g
Standards
- • EN ISO 13849-1
Product Features
- • ATEX Zon 2 ve 22 için patlama koruması_x000D_
- • Metal gövde_x000D_
- • Yağ ve benzine karşı iyi direnç_x000D_
- • 40,5 mm x 76 mm x 38 mm_x000D_
- • Aktüatör başlıkları 4 x 90° yeniden konumlandırılabilir_x000D_
- • EN 50041 montaj detayları_x000D_
- • 1 Kablo girişi M20 x 1,5
Technical Specifications
Note
All belirtimler iletken end included.
Wire Cross-Section
13 AWG
Lever Material
Metal film
Mission Time
20 Year(s)
Gross Weight
360 g
Housing Material
Aluminium
Contact Material
Silver
Manufacturer Declaration
ATEX Zone 2 and 22
Min. Cable Cross-Section
0.75 mm²
Sensor Length
60.6 mm
Max. Cable Cross-Section
2.5 mm²
Cylinder Material
Plastik
Actuation Element
With roller lever
IP Protection Class
IP67
Max. Bounce Time
2 ms
Ambient Temperature
-20 ... +60 °C
Sensor Width
40.5 mm
Thermal Test Current
0.4166666666678793
Switching Element
2 NA contact
Switching Principle
Slow hareket Kademeli with contacts slow hareket
Max. Impact Energy
4 J
Mechanical Life (min.)
30,000,000 Cycles
Housing Design Form
Standard construction design
Sensor Height
134 mm
Min. Actuation Torque
0.3 Nm
Note (Transfer Time)
Transition time actuation to speed depends on
Terminal Connection
Threaded terminal block M20 x 1,5
Max. Actuation Speed
2.5 m/s
Note (Actuation Speed)
Switch eksenine 30° actuation at the angle actuation speed
Explosion Protection Definition
D II 3G Ex nC IIC T5 Gc X D II 3D Ex tc IIIC T90°C Dc X
Housing Coating Material
Painted
Min. Cable Gland Cross-Section
7 mm
Max. Cable Gland Cross-Section
12 mm
Explosion Protection Zones
2 22
Explosion Protection Category
3G 3D
Actuator Type (EN 50041)
A
Utilization Category AC-15
0.16666666666787933
Utilization Category DC-13
0.16666666666787933
Number of Auxiliary Contacts
2
Max. Switching Frequency
5,000 /h
Impulse Withstand Voltage (Uimp)
6 kV
Explosion Protection Regulations
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31
Rated Insulation Voltage (Uᵢ)
500 V