FWS 1206 A
Order No 101170057
Article Code 101170057
Certificates cULus
Schmersal Emniyetli Sinyal İşleme Güvenlik Rölesi ve Kontrol Modülleri

FWS 1206 A

Product Description

  • • Voltage: 24 VDC | Dimensions: 22.5mm×100mm×121mm | Weight: 200 g | Certification: cULus | PL d

Standards

  • • EN IEC 61508

Product Features

  • • Detects standstill using 1 or 2 impulse sensors_x000D_
  • • Uses additional standstill signal, e.g. PLC as second input channel_x000D_
  • • 2 safety contacts_x000D_
  • • 2 sinyal çıkışı

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Depth 121 mm
Category 3
Faults Safety of the relay not pulling/not releasing failure, Input/relay kontrol devre failure, Proximity switch failure, Evaluated kanal failure, Inductive proximity switch connection interruption
General Note Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width 22.5 mm
Height 100 mm
PFH Value 1.00 x 10⁻⁷ /h
Number of LEDs 1
Impact Resistance 30 g / 11 ms
Application Note Safe durma monitoring
Mission Time 20 Year(s)
Gross Weight 200 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact Material Ag-Ni 10 and 0,2 µm gold coated
Pollution Degree 3
Min. Cable Cross-Section 0.2 mm²
Vibration Resistance 10 ... 55 Hz, Amplitude 0.35 mm
Clip Tightening Torque 0.6 Nm
Max. Cable Cross-Section 2.5 mm²
Climatic Resistance EN 60068-2-3 BG-GS-ET-14
Stop Category 0
Ambient Temperature +0 ... +55 °C
Performance Level d
Reset Edge Detection Yes
Thermal Test Current 0.25
Operating Voltage 24 VDC -15 % / +15 %
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical Life (min.) 20,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Max. Transmission Resistance 40 Ω
Note (ISD - Faults) The following fault safety monitoring modules by kaydedilir and ISD by is shown.
Wire Breakage Detection Yes
Production End Date 31.12.2024
Terminal Connection Solid or esnek, threaded terminal block M20 x 1,5
Suitable SIL Applications 2
Connection Diagram Note Connection diagram, guard door closed and enerji cut off in the state is shown. ISD tables in the appendix. A guard door monitoring.
Number of Safety Contacts 2
IP Protection (Mounting Area) IP54
Current Utilization Cat. AC-15 0.125
Current Utilization Cat. DC-13 0.08333333333212067
Overvoltage Category II
Min. Switching Capacity 10 mA
Rated Operating Voltage 24 VDC
Number of Signal Outputs 2
AC Control Voltage 50Hz min. 20.4 VAC
AC Control Voltage 60Hz min. 20.4 VAC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 0.08333333333212067
Earth Connection Detection Yes
AC Control Voltage 50Hz max. 26.4 VAC
AC Control Voltage 60Hz max. 26.4 VAC
Input Signal LOW (Signal 0) 0 … 2 VDC
Impulse Withstand Voltage (Uimp) 4.8 kV
Input Signal HIGH (Signal 1) 10 … 30 VDC
Storage/Transport Temperature -25 ... +70 °C
Integrated System Diagnostics Status Yes
DC Min. Rated Control Voltage 20.4 VDC
DC Max. Rated Control Voltage 28.8 VDC
Max. Electrical Power Consumption 5 W
Number of Undelayed Semiconductor Outputs (with Signal Function) 2
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.