SRB200EXi-1A
Order No 101196286
Article Code 101196286
Certificates ATEX IECEx INMETRO PESO
Schmersal Emniyetli Sinyal İşleme Güvenlik İzleme Modülleri

SRB200EXi-1A

Product Description

  • • Voltage: 24 VDC | Dimensions: 22.5mm×100mm×121mm | Weight: 230 g | Certification: ATEX IECEx INMETRO PESO | Contacts: 2 NC

Standards

  • • EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 61508

Product Features

  • • Automatic reset function_x000D_
  • • 2 safety contacts_x000D_
  • • Suitable for signal processing of emergency stop control devices, interlocking equipment, etc

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Depth 121 mm
General Note Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width 22.5 mm
SIL Stop 0 3
Height 100 mm
Number of LEDs 5
Impact Resistance 10 g / 11 ms
EMC Class EMC Directive
Application Note Safety sensor Protection system Acil durdurma butonu Pull wire acil durdurma switch
Mission Time 15 Year(s)
Current Consumption 57 mA
Category Stop 0 4
Gross Weight 230 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact Material AgSn0. self-cleaning, positive drive
Pollution Degree 2
Min. Cable Cross-Section 0.25 mm²
Vibration Resistance 10 ... 55 Hz, Amplitude 0.35 mm
DC Level Stop 0 ≥ 99 %
Clip Tightening Torque 0.6 Nm
Max. Cable Cross-Section 2.5 mm²
PFH Value Stop 0 2.00 x 10⁻⁸ /h
Terminal (Mechanical) Threaded terminal block
Climatic Resistance EN 60068-2-78
Ripple Voltage 0.1
Stop Category 0
Ambient Temperature -25 ... +60 °C
Operating Voltage 24 VDC -10 % / +20 %
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical Life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Max. Transmission Resistance 30 Ω
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Explosion Protection Definition D II 3 G Ex nA nC IIC T5 Gc (Installation SRB, in Zone 2) D II (2) G [Ex ib Gb] IIC D II (2) D [Ex ib Db] IIIC
Connection Diagram Note BNS serisinden magnetic safety sensor with 1 guard door monitoring. ISO 13849-1 Category 3 classification for external contactor fault documentation of is required. PL e and Category 4'e up to a guard door assurance below is taken.
Permissible Cable Type Single core solid / esnek
Number of Safety Contacts 2
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Explosion Protection Zones 2
Explosion Protection Category 3G
Utilization Category AC-15 0.08333333333212067
Utilization Category DC-13 0.08333333333212067
Performance Level Stop 0 e
Overvoltage Category III
Electrical Power Consumption 3 W
Rated Operating Voltage 24 VDC
IP Protection (Terminal Block) IP20
Earth Connection Detection Yes
Impulse Withstand Voltage (Uimp) 4 kV
Explosion Protection Regulations EN IEC 60079-0 EN 60079-11 EN IEC 60079-15
Storage/Transport Temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 20 ms
DC Min. Rated Control Voltage 20.4 VDC
Min. Common Cause Failure (CCF) 65
DC Max. Rated Control Voltage 28.8 VDC
Emergency Stop Release Delay (Max.) 20 ms
Release Delay on Power Failure 20 ms
Number of NC (Normally Closed) Contacts 2
Pull-In Delay on Automatic Start 300 ms
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3