SRB302X3-24VAC/DC-230VAC
Order No 101181616
Article Code 101181616
Certificates cULus
Schmersal Emniyetli Sinyal İşleme Güvenlik İzleme Modülleri

SRB302X3-24VAC/DC-230VAC

Product Description

  • • Voltage: 24 ... 230 VAC | Dimensions: 45mm×100mm×121mm | Weight: 450 g | Certification: cULus | Contacts: 2 NC | PL e

Standards

  • • EN IEC 60947-5-1 EN IEC 61508

Product Features

  • • Suitable for the signal processing of outputs with contact sensors_x000D_
  • • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains_x000D_
  • • 3 güvenlik kontağı, STOP 0_x000D_
  • • 2 sinyal çıkışı

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Depth 121 mm
Category 4
General Note Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width 45 mm
Height 100 mm
PFH Value 2.00 x 10⁻⁸ /h
Number of LEDs 3
Impact Resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Protection system Acil durdurma butonu Pull wire acil durdurma switch Safety light curtain
Mission Time 20 Year(s)
Gross Weight 450 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact Material AgSn0. self-cleaning, positive drive
Start Input Yes
Pollution Degree 2
Min. Cable Cross-Section 0.25 mm²
Vibration Resistance 10 ... 55 Hz, Amplitude 0.35 mm
Electronic Fuse Yes
Frequency Range 50 Hz 60 Hz
Clip Tightening Torque 0.6 Nm
Max. Cable Cross-Section 2.5 mm²
Terminal (Mechanical) Threaded terminal block
Climatic Resistance EN 60068-2-78
Ripple Voltage 0.1
Stop Category 0
Ambient Temperature -25 ... +60 °C
Performance Level e
Reset Edge Detection Yes
Operating Voltage 24 ... 230 VAC -15 % / +10 %
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical Life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Voltage Range Type AC
Suitable SIL Applications 3
Connection Diagram Note Evaluation requirements: switch-off pauses of 250 µs - 1500 µs must be tolerated. The safety sensor's 250 µs switch-off time is extended according to cable length. Typically 500 µs is achieved with 100 m of cable.
Permissible Cable Type Single core solid / esnek
Number of Safety Contacts 3
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Utilization Category AC-15 0.25
Utilization Category DC-13 0.25
Number of Auxiliary Contacts 2
Overvoltage Category III
Electrical Power Consumption 5 VA
Rated Operating Voltage 24 ... 230 VAC
AC Control Voltage 50Hz min. 20.4 VAC
IP Protection (Terminal Block) IP20
Earth Connection Detection Yes
AC Control Voltage 50Hz max. 26.4 VAC
Impulse Withstand Voltage (Uimp) 4 kV
Storage/Transport Temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 20 ms
Diagnostic Coverage (DC) Level > 99 %
DC Min. Rated Control Voltage 20.4 VDC
Min. Common Cause Failure (CCF) 65
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Konum relay K2 Konum relay K1
Emergency Stop Release Delay (Max.) 20 ms
Release Delay on Power Failure 60 ms
Number of NC (Normally Closed) Contacts 2