SSW301HV-115V
Order No 101182592
Article Code 101182592
Certificates cULus CCC
Schmersal Emniyetli Sinyal İşleme Güvenlik Rölesi ve Kontrol Modülleri

SSW301HV-115V

Product Description

  • • Voltage: 115 VAC | Dimensions: 90mm×83mm×127mm | Weight: 500 g | Certification: cULus CCC

Standards

  • • EN ISO 13849-1 EN IEC 61508

Product Features

  • • Fail-safe standstill monitors_x000D_
  • • This fail-safe standstill monitor has the particular advantage that no adjustment for a required-value is needed during comissioning._x000D_
  • • 3 güvenlik kontağı, STOP 0_x000D_
  • • Control category 4 to ISO 13849-1

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Depth 127 mm
General Note Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width 90 mm
SIL Stop 0 3
Height 83 mm
Number of LEDs 5
Impact Resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Safe durma monitoring
Mission Time 20 Year(s)
Category Stop 0 4
Gross Weight 500 g
Housing Material Cam elyaf takviyeli termoplastik
Contact Material AgSn0 + Au, self-cleaning, positive drive
Pollution Degree 2
Min. Cable Cross-Section 0.25 mm²
Vibration Resistance 10 ... 55 Hz, Amplitude 0.35 mm
DC Level Stop 0 ≥ 99 %
Clip Tightening Torque 0.6 Nm
Max. Cable Cross-Section 2.5 mm²
PFH Value Stop 0 2.00 x 10⁻⁸ /h
Climatic Resistance EN 60068-2-78
Stop Category 0
Ambient Temperature -25 ... +45 °C
Operating Voltage 115 VAC -15 % / +10 %
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical Life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Terminal Connection Solid or esnek, threaded terminal block M20 x 1,5
Connection Diagram Note OUTPUT: Enable safety contacts 13-14, 23-24 closed
Number of Safety Contacts 3
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. AC-15 0.25
Current Utilization Cat. DC-13 0.25
Performance Level Stop 0 e
Number of Auxiliary Contacts 1
Min. Switching Capacity 10 mA
Rated Operating Voltage 115 VAC
AC Control Voltage 50Hz min. 97.8 VAC
AC Control Voltage 60Hz min. 97.8 VAC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 0.08333333333212067
Earth Connection Detection Yes
AC Control Voltage 50Hz max. 126.5 VAC
AC Control Voltage 60Hz max. 126.5 VAC
Impulse Withstand Voltage (Uimp) 4 kV
Storage/Transport Temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Min. Common Cause Failure (CCF) 65
Displayed Operating States OUTPUT, green: serbest release switching condition UB: Supply voltage open ERR: Hata fonksiyonel fault
Max. Electrical Power Consumption 4 W
Emergency Stop Release Delay (Max.) 15 ms
Pull-In Delay on Automatic Start (After Standstill Detection) 7,000 ms