Order No
101182592
Article Code
101182592
Certificates
cULus CCC
Schmersal
Emniyetli Sinyal İşleme
Güvenlik Rölesi ve Kontrol Modülleri
SSW301HV-115V
Product Description
- • Voltage: 115 VAC | Dimensions: 90mm×83mm×127mm | Weight: 500 g | Certification: cULus CCC
Standards
- • EN ISO 13849-1 EN IEC 61508
Product Features
- • Fail-safe standstill monitors_x000D_
- • This fail-safe standstill monitor has the particular advantage that no adjustment for a required-value is needed during comissioning._x000D_
- • 3 güvenlik kontağı, STOP 0_x000D_
- • Control category 4 to ISO 13849-1
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Depth
127 mm
General Note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
90 mm
SIL Stop 0
3
Height
83 mm
Number of LEDs
5
Impact Resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Safe durma monitoring
Mission Time
20 Year(s)
Category Stop 0
4
Gross Weight
500 g
Housing Material
Cam elyaf takviyeli termoplastik
Contact Material
AgSn0 + Au, self-cleaning, positive drive
Pollution Degree
2
Min. Cable Cross-Section
0.25 mm²
Vibration Resistance
10 ... 55 Hz, Amplitude 0.35 mm
DC Level Stop 0
≥ 99 %
Clip Tightening Torque
0.6 Nm
Max. Cable Cross-Section
2.5 mm²
PFH Value Stop 0
2.00 x 10⁻⁸ /h
Climatic Resistance
EN 60068-2-78
Stop Category
0
Ambient Temperature
-25 ... +45 °C
Operating Voltage
115 VAC -15 % / +10 %
Feedback Circuit
Yes
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical Life (min.)
10,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Max. Transmission Resistance
40 Ω
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Terminal Connection
Solid or esnek, threaded terminal block M20 x 1,5
Connection Diagram Note
OUTPUT: Enable safety contacts 13-14, 23-24 closed
Number of Safety Contacts
3
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
0.25
Current Utilization Cat. DC-13
0.25
Performance Level Stop 0
e
Number of Auxiliary Contacts
1
Min. Switching Capacity
10 mA
Rated Operating Voltage
115 VAC
AC Control Voltage 50Hz min.
97.8 VAC
AC Control Voltage 60Hz min.
97.8 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
0.08333333333212067
Earth Connection Detection
Yes
AC Control Voltage 50Hz max.
126.5 VAC
AC Control Voltage 60Hz max.
126.5 VAC
Impulse Withstand Voltage (Uimp)
4 kV
Storage/Transport Temperature
-40 ... +85 °C
Integrated System Diagnostics Status
Yes
Min. Common Cause Failure (CCF)
65
Displayed Operating States
OUTPUT, green: serbest release switching condition UB: Supply voltage open ERR: Hata fonksiyonel fault
Max. Electrical Power Consumption
4 W
Emergency Stop Release Delay (Max.)
15 ms
Pull-In Delay on Automatic Start (After Standstill Detection)
7,000 ms