Depth
58 mm
Montaj
Snaps onto standard DIN rail to EN 60715
Notice
for max. 50 000 switching cycles/year and max. 80% contact load
Kategori
3
Genel Not
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Genişlik
48 mm
PFH value
1.00 x 10⁻⁷ /h
EMC rating
EN 61000-4-6 | EN 61000-4-3 | IEC 61000-6-2
Yükseklik
96 mm
Kablo Kesiti
1.5 mm²
Voltage type
DC
Darbe Dayanımı
30 g / 11 ms
Stop-Category
0
Görev Süresi
20 Year(s)
Net Ağırlık
125 g
Number of LEDs
1
Frequency range
50 Hz | 60 Hz
Brüt Ağırlık
125 g
Gövde Malzemesi
Glass-fibre, reinforced thermoplastic
Kontak Malzemesi
AgCdO
Kirlenme Derecesi
2
Operating voltage
24 VDC -15 % / +15 %
Titreşim Dayanımı
10...55 Hz, Genlik 0.35 mm, ± %15
Maks. Kablo Kesiti
1.5 mm²
Çalışma Akımı
100 mA
Ortam Sıcaklığı
+0 ... +55 °C
Performans Seviyesi
d
Termal Test Akımı
5 A
Mekanik Ömür (min.)
50 000 000
Allowed type of cable
solid single-wire | flexible
Note (Wiring diagram)
To secure one or a number of guard doors up to PL c and Category 1 | Monitoring further guard doors: Further magnetic safety sensors can be connected to S2 in a similar way to those on S1. | Monitoring a number of guard doors using magnetic safety sensors BNS range | The wiring diagram is shown with guard doors closed and in de-energised condition.
Terminal Bağlantısı
Screw terminals
Cross-circuit detection
Yes
Wire breakage detection
Yes
Automatic reset function
Yes
Min. Ortam Sıcaklığı
+0 °C
Note (Delivery capacity)
Not available!
Güvenlik Kontak Sayısı
1
Maks. Ortam Sıcaklığı
+55 °C
Note (Contact resistance)
in new state
Indicated operating states
Authorised operation
Aşırı Gerilim Kategorisi
III
Contact resistance, maximum
0.1 Ω
Nominal Çalışma Voltajı
24 VDC ± 15 % | 24 VDC
Switching capacity, maximum
250 VAC | 2 A | 24 VDC | 8 A
Switching capacity, minimum
10 VDC | 10 mA
Electrical power consumption
2.5 W
Note (application conditions)
Safety sensor | Guard system
Conduction resistance, maximum
40 Ω
Darbe Dayanım Gerilimi (Uimp)
4.8 kV
Depolama / Taşıma Sıcaklığı
-25 ... +75 °C | -25 ... +70 °C
Pull-in delay at RESET, typically
20 ms
Current, Utilisation category AC-15
6 A
Current, Utilisation category DC-13
6 A
Integral system diagnostics, status
Yes
Voltage, Utilisation category AC-15
230 VAC
Voltage, Utilisation category DC-13
24 VDC
NA (Normalde Açık) Kontak Sayısı
2
Rated control voltage at DC, maximum
27.6 VDC
NK (Normalde Kapalı) Kontak Sayısı
4
IP Degree of protection of the enclosure
IP40
Rated control voltage at AC 50 Hz, maximum
26.4 VAC
Rated control voltage at AC 60 Hz, maximum
26.4 VAC
Storage and transport temperature, maximum
+70 °C
Storage and transport temperature, minimum
-25 °C
Rated AC voltage for controls at DC minimum
20.4 VDC
Reset after disconnection of supply voltage
Yes
IP Degree of protection of clips or terminals
IP20
Rated AC voltage for controls, 50 Hz, minimum
20.4 VAC
Rated AC voltage for controls, 60 Hz, minimum
20.4 VAC
Drop-out delay in case of emergency, typically
20 ms
IP Degree of protection of the installation space
IP54
Drop-out delay in case of power failure, typically
80 ms
Pull-in delay at automatic start, maximum, typically
100 ms
Safety Integrity Level (SIL), suitable for applications in
2