Not
The diagnostic output are not safety relevant outputs!
EPLAN
Yes
PIN 1
A1 Supply voltage UB
PIN 2
X2 Safety input 2
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
E3 Control input 3
PIN 7
Y2 Safety output 2
PIN 8
E2 Control input 2
Coding
Bireysel kodlama, çoklu öğretme (teach-in)
CADENAS
Yes
Kategori
4
PFD value
9.00 x 10⁻⁵ | 1.60 x 10⁻⁴
PFH value
1.00 x 10⁻⁹ /h | 1.80 x 10⁻⁹ /h
Voltage type
DC
Darbe Dayanımı
30 g / 11 ms
Emergency exit
Yes
Görev Süresi
20 Year(s)
Net Ağırlık
846 g
Bağlantı Tipi
Connector M12, 8-pole
Brüt Ağırlık
846 g
Gövde Malzemesi
Light alloy die-casting
Protection class
III
Safety functions
Yes
Kirlenme Derecesi
3
Operating voltage
24 VDC -15 % / +10 % (PELV to EN 60204-1)
Scope of delivery
Actuator must be ordered separately.
Sensör Uzunluğu
65.3 mm
Titreşim Dayanımı
10 … 150 Hz, genlik 0.35 mm
Frequency band RFID
125 kHz
IP Koruma Sınıfı
IP66 | IP67
Ortam Sıcaklığı
-20 ... +55 °C
Performans Seviyesi
e
Sensör Genişliği
77.8 mm
Çalışma Prensibi
RFID | Magnetic field
Mekanik Ömür (min.)
1 000 000
Sensör Yüksekliği
166.7 mm
Interlocking principle
iki durumlu
Cross-circuit detection
Yes
Short circuit detection
Yes
Min. Ortam Sıcaklığı
-20 °C
Minimum distance devices
30 mm
Note (Delivery capacity)
Not available!
Note (Relative humidity)
non-condensing | non-icing
Voltage drop Ud, maximum
2 V
Maks. Ortam Sıcaklığı
+55 °C
Recommendation (actuator)
AZM400-B1
Type of the fixing screws
2x M6
Design of control elements
short-circuit proof, p-type
Kullanım Kategorisi DC-13
24 VDC / 0.25 A | 24_0.05
Note (Mechanical lifetime)
Which have a lateral force Ftrans = 100 N: 100.000 operations
Relative humidity, maximum
93 %
Time to readiness, maximum
1 500 ms
Utilisation category DC-12
24 VDC / 0.25 A | 24 VDC / 0.05 A | 24_0.05 | 24_0.25
Aşırı Gerilim Kategorisi
3 | III
Designation, Control inputs
E1 ve E2 (p-anahtarlama), E3 (n-anahtarlama)
Designation, Safety outputs
Y1 and Y2
Holding force Fmax, maximum
13 000 N
Leakage current Ir, maximum
1.5 mA
Nominal Çalışma Voltajı
24 VDC
Number of diagnostic signals
1
Solenoid interlock monitored
Yes
Switching frequency, maximum
0.3 Hz
Test pulse duration, maximum
5 ms | 0.5 ms
Test pulse interval, maximum
40 ms
Test pulse interval, typical
1 000 ms
Darbe Dayanım Gerilimi (Uimp)
0.8 kV
Tightening torque of the screw
8 Nm
Classification ZVEI CB24I, Sink
C1 | C0 | C2
Current draw during bolt stroke
600 mA
Designation, Diagnostic outputs
OUT
Electrical fuse rating, maximum
2 A
Note (Type of the fixing screws)
Property class min. 10.9
Transmitter output RFID, maximum
-6 dBm
Classification ZVEI CB24I, Source
C1 | C3 | C2
Depolama / Taşıma Sıcaklığı
-40 ... +85 °C
Nominal Yalıtım Gerilimi (Uᵢ)
32 VDC
No-load supply current I0, typical
100 mA
Permissible residual drive current
1.5 mA
Current consumption at 24V, maximum
10 mA
Current consumption at 24V, minimum
5 mA
Current, Utilisation category DC-12
0.05 A | 0.25 A
Current, Utilisation category DC-13
0.05 A | 0.25 A
Gerekli Nominal Kısa Devre Akımı
100 A
Integral system diagnostics, status
Yes
Note (Lateral force at bolt return)
Does not apply to emergency exit, Bowden cable and manual release
Number of fail-safe digital outputs
2
Open / close cycle (motor), minimum
3 s
Voltage, Utilisation category DC-12
24 VDC
Voltage, Utilisation category DC-13
24 VDC
External wire and device fuse rating
2 A gG (Connector M12, 8-pole) | 2 A gG
Protection class (Operating resource)
3
Coding level according to EN ISO 14119
High
Note (LED switching conditions display)
Error / functional defect: LED red | Operating condition: LED green | Supply voltage UB: LED green
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-40 °C
Switching thresholds of the control inputs
15 V … 30 V (High) | −3 V … 5 V (Low)
Allowable discrepancy time (input), maximum
10 s
Allowed distance interlock to actuator, maximum
7 mm
Allowed distance interlock to actuator, minimum
1 mm
Holding force FZh in accordance with EN ISO 14119
10 000 N
Minimal average cycle time (with continuous operation)
20 s
Permissible installation altitude above sea level, maximum
2 000 m
Safety Integrity Level (SIL), suitable for applications in
3
Lateral force at bolt return, maximal (against locked door)
300 N
Reaction time, switching off safety outputs via actuator, maximum
100 ms
Angular misalignment between solenoid interlock and actuator, maximum
2 °