Not
Observe the maximum tightening torque of the fixing screws used.
PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN Solenoid control
Coding
Bireysel kodlama, çoklu öğretme (teach-in)
Montaj
mounting holes plain
CADENAS
Yes
Kategori
4
Latching
Yes
PFD value
8.90 x 10⁻⁵
PFH value
1.10 x 10⁻⁹ /h
Unlocking
Rotating unlatcher
Voltage type
DC
Darbe Dayanımı
30 g / 11 ms
Series-wiring
Yes
Görev Süresi
20 Year(s)
Latching force
40 N (+/- 25%) | 40 N
Manual release
Yes
Net Ağırlık
306 g
Property class
8.8 / 80
Actuating angle
180 °
Brüt Ağırlık
306 g
Gövde Malzemesi
Light alloy die cast and plastic (glass-fibre reinforced thermoplastic)
Protection class
III
Safety functions
Yes
Kirlenme Derecesi
3
Operating voltage
24 VDC -15 % / +10 % (PELV to EN 60204-1)
Sensör Uzunluğu
119.5 mm
Titreşim Dayanımı
10 … 55 Hz, genlik 1 mm
Actuator monitored
Yes
Note (Latch force)
+/- 25%
Çalışma Akımı
1 200 mA
Frequency band RFID
125 kHz
IP Koruma Sınıfı
IP66 | IP69 | IP67
Ortam Sıcaklığı
-20 ... +55 °C
Performans Seviyesi
e
Sensör Genişliği
40 mm
Çalışma Prensibi
RFID
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Sensör Yüksekliği
20 mm
Switching thresholds
-3 V … 5 V (Low) | −3 V … 5 V (Low) | 15 V … 30 V (High)
Magnet switch-on time
100 %
Note (Manual release)
Manual release from side
Interlocking principle
iki durumlu
Terminal Bağlantısı
Connector plug M12, 8-pole, A-coded
Cross-circuit detection
Yes
Maks. Aktüasyon Hızı
0.5 m/s
Short circuit detection
Yes
Min. Ortam Sıcaklığı
-20 °C
Note (Delivery capacity)
Not available!
Note (Relative humidity)
non-condensing | non-icing
Voltage drop Ud, maximum
2 V
Duration of risk, maximum
200 ms
Maks. Ortam Sıcaklığı
+55 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator)
AZM40-B1-PH
Type of the fixing screws
2x M5
Design of control elements
OSSD, short-circuit proof, p-type | short-circuit proof, p-type
Designation, Safety inputs
X1 and X2
Kullanım Kategorisi DC-13
24 VDC / 0.25 A | 24_0.05
Mekanik Montaj Koşulları
arbitrarily
Note (Mechanical lifetime)
from device version V2 (V1 = 200.000 actuator cycles)
Relative humidity, maximum
93 %
Time to readiness, maximum
4 000 ms
Utilisation category DC-12
24 VDC / 0.25 A | 24_0.05 | 24 VDC / 0.05 A | 24_0.25
Aşırı Gerilim Kategorisi
3 | III
Current consumption at 24 V
10 ... 15 mA | 5 mA
Designation, Magnet control
IN
Designation, Safety outputs
Y1 and Y2
Holding force Fmax, maximum
2 600 N
Leakage current Ir, maximum
0.5 mA
Nominal Çalışma Voltajı
24 VDC - 15 % / + 10 % (stabilised PELV) | 24 VDC
Switching frequency, maximum
0.25 Hz
Test pulse duration, maximum
5 ms | 1 ms | 0.5 ms
Test pulse interval, minimum
40 ms | 100 ms
Test pulse interval, typical
1 000 ms
Darbe Dayanım Gerilimi (Uimp)
0.8 kV
Classification ZVEI CB24I, Sink
C1 | C0 | C2
Designation, Diagnostic outputs
OUT
Length of sensor chain, maximum
200 m
Transmitter output RFID, maximum
-6 dBm
Classification ZVEI CB24I, Source
C3 | C1 | C2
Depolama / Taşıma Sıcaklığı
-40 ... +85 °C
Nominal Yalıtım Gerilimi (Uᵢ)
32 VDC
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, maximum
100 mA
Number of digital fail-safe inputs
2
Assured switching distance "ON" Sao
1 mm
Current consumption at 24V, maximum
15 mA
Current consumption at 24V, minimum
10 mA
Current, Utilisation category DC-12
0.05 A | 0.25 A
Current, Utilisation category DC-13
0.05 A | 0.25 A
Gerekli Nominal Kısa Devre Akımı
100 A
Integral system diagnostics, status
Yes
Mechanical lifetime, locking cycles
1 000 000
Number of fail-safe digital outputs
2
Voltage, Utilisation category DC-12
24 VDC
Voltage, Utilisation category DC-13
24 VDC
Assured switching distance "OFF" Sar
8 mm
External wire and device fuse rating
2 A gG
Mechanical lifetime, actuator cycles
500 000
Protection class (Operating resource)
3
Coding level according to EN ISO 14119
High
Tightening torque of the fixing screws
4 ... 6 Nm
Note (LED switching conditions display)
Error / functional defect: LED red | Operating condition: LED green | Supply voltage UB: LED green
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-40 °C
Tightening torque of the fixing screws, maximum
6 Nm
Tightening torque of the fixing screws, minimum
4 Nm
Holding force FZh in accordance with EN ISO 14119
2 000 N
Current consumption magnet at switching moment, peak
600 mA / 100 ms
Permissible installation altitude above sea level, maximum
2 000 m
Safety Integrity Level (SIL), suitable for applications in
3
Reaction time, switching off safety outputs via actuator, maximum
100 ms
Angular misalignment between solenoid interlock and actuator, maximum
2 °
Reaction time, switching off safety outputs via safety inputs, maximum
1.5 ms