PIN 1
1A1 Ue: (1)
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output OUT
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN On-site acknowledgment
Kategori
4
Genel Not
On-site acknowledgment | When safety gate monitoring by the safety sensor CSP 34F2 is required, an acknowledge button should be positioned so that the danger area can be viewed. When the button is pushed, a 24 VDC signal is generated at the reset input of the CSP 34F2. | If the gate is closed the safety outputs are released with the negative signal edge. After the gate is opened it needs to be acknowledge before it can be released again.
PFH value
3.60 x 10⁻⁹ /h
Cascadable
Yes
EMC rating
IEC 61000-6-2
Active area
Glass-fibre, reinforced thermoplastic | lateral
Voltage type
DC
Darbe Dayanımı
30 g / 11 ms
Görev Süresi
20 Year(s)
Net Ağırlık
140 g
Number of LEDs
3
Bağlantı Tipi
Connector plug M12, 8-pole
Sensor topology
Sensor for series wiring
Actuating panels
lateral
Brüt Ağırlık
140 g
Current derating
Ambient temperature -25°C … +65°C: ≤ 0.25 A | Ambient temperature -25°C … +70°C: ≤ 0.1 A
Gövde Malzemesi
Glass-fibre, reinforced thermoplastic
Protection class
II
Safety functions
Yes
Diagnostic output
Yes
Kirlenme Derecesi
3
Operating voltage
24 VDC -15 % / +10 %
Repeat accuracy R
0.5 mm
Scope of delivery
Actuator must be ordered separately.
Sensör Uzunluğu
27 mm
Titreşim Dayanımı
10 … 55 Hz, genlik 1 mm
Çalışma Akımı
600 mA | 50 mA
IP Koruma Sınıfı
IP67 | IP65
Ortam Sıcaklığı
-25 ... +70 °C
Performans Seviyesi
e
Sensör Genişliği
35 mm
Çalışma Prensibi
Endüktif
Sensör Yüksekliği
108.2 mm
Utilisation category
DC-12
Interfering radiation
IEC 61000-6-4
On-site acknowledgment
Yes
Reaction time, maximum
30 ms
Cross-circuit detection
Yes
Short circuit detection
Yes
Min. Ortam Sıcaklığı
-25 °C
Note (Delivery capacity)
Not available!
Note (Repeat accuracy R)
Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 30 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 8 mm.
Switch distance, typical
11 mm
Voltage drop Ud, maximum
0.5 V | 5 V
Duration of risk, maximum
60 ms
Housing construction form
Block
Maks. Ortam Sıcaklığı
+70 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator)
CSP 34-S-1
Design of control elements
p-type
Kullanım Kategorisi DC-13
24 VDC / 0.25 A | 0.05 A | 24 VDC | 24 VDC / 0.05 A
Mekanik Montaj Koşulları
not flush
Utilisation category DC-12
24 VDC | 0.05 A | 24 VDC / 0.05 A | 24 VDC / 0.25 A | 24_0.05 | 24_0.25
Aşırı Gerilim Kategorisi
3 | III
Leakage current Ir, maximum
0.5 mA
Nominal Çalışma Voltajı
24 VDC
Switching frequency, approx.
3 Hz
Recommended safety switchgear
SRB-E-301ST | SRB-E-201LC | PROTECT PSC1
Darbe Dayanım Gerilimi (Uimp)
0.8 kV
Electrical fuse rating, maximum
2 A
Rated operating voltage, maximum
26.4 VDC
Rated operating voltage, minimum
20.4 VDC
Depolama / Taşıma Sıcaklığı
-25 ... +85 °C | -40 ... +85 °C
Nominal Yalıtım Gerilimi (Uᵢ)
32 VAC/DC
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical
100 mA
Number of series-wiring of sensors
31
Assured switching distance "ON" Sao
8 mm
Current, Utilisation category DC-12
0.05 A | 0.25 A
Current, Utilisation category DC-13
0.25 A
Gerekli Nominal Kısa Devre Akımı
100 A
Integral system diagnostics, status
Yes
Note (Electrical data, Fuse rating)
(Devre kesici)
Number of fail-safe digital outputs
2
Voltage, Utilisation category DC-12
24 VDC
Voltage, Utilisation category DC-13
24 VDC
Absicherung des Sicherheitsausganges
short-circuit proof
Assured switching distance "OFF" Sar
15 mm
Protection class (Operating resource)
2
Hysteresis (Switching distance), maximum
1.5 mm
Rated operating current (safety outputs)
250 mA
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-25 °C
Output current, (fail-safe output), maximum
0.25 A
Input for reset pushbutton, with edge monitoring
Yes
Number of semi-conductor outputs with signaling function
1
Safety Integrity Level (SIL), suitable for applications in
3
Input for enabling pushbutton, suitable for automatic start
Yes