EPLAN
Yes
PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN Solenoid control
Coding
Evrensel kodlama
Kategori
4
Genel Not
(-3215) Device with inverted diagnostic output | (-2930) Device type Z without locking time
PFH value
3.54 x 10⁻⁹ /h
Voltage type
DC
Darbe Dayanımı
30 g / 11 ms
Power to lock
Yes
Series-wiring
Yes
Görev Süresi
20 Year(s)
Latching force
15 / 30 / 45 / 60 / 100 N
Bağlantı Tipi
Connector M12, 8-pole
Gövde Malzemesi
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Protection class
III
Safety functions
Yes
Kirlenme Derecesi
3
Operating voltage
24 VDC -15 % / +10 % (PELV to EN 60204-1)
Relative humidity
30 ... 95 %
Scope of delivery
Actuator must be ordered separately.
Sensör Uzunluğu
40 mm
Titreşim Dayanımı
10 … 150 Hz, genlik 0.35 mm / 5 g
Actuator monitored
Yes
Çalışma Akımı
1 100 mA | 50 mA
IP Koruma Sınıfı
IP67 | IP65
Ortam Sıcaklığı
-25 ... +55 °C
Performans Seviyesi
e
Sensör Genişliği
40 mm
Çalışma Prensibi
Endüktif
Mekanik Ömür (min.)
1 000 000
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Sensör Yüksekliği
177.5 mm
Switching thresholds
-3 V … 5 V (Low) | −3 V … 5 V (Low) | 15 V … 30 V (High)
Magnet switch-on time
100 %
Electrical fuse rating
short-circuit proof, p-type
Reaction time, maximum
150 ms
Cross-circuit detection
Yes
Short circuit detection
Yes
Holding force, typically
750 N
Min. Ortam Sıcaklığı
-25 °C
Minimum distance devices
100 mm
Note (Relative humidity)
non-condensing | non-icing
Voltage drop Ud, maximum
2 V | 1 V
Duration of risk, maximum
150 ms
Holding force, guaranteed
500 N
Maks. Ortam Sıcaklığı
+55 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator)
MZM 100-B1.1
Type of the fixing screws
2x M6
Design of control elements
short-circuit proof, p-type
Designation, Safety inputs
X1 and X2
Kullanım Kategorisi DC-13
24 VDC / 0.25 A | 24_0.05
Note (Mechanical lifetime)
Actuating speed ≤ 0.5 m/s | Operations for door weights ≤ 5 kg
Operating voltage, maximum
26.4 VDC
Operating voltage, minimum
20.4 VDC
Relative humidity, maximum
95 %
Relative humidity, minimum
30 %
Time to readiness, maximum
4 000 ms
Aşırı Gerilim Kategorisi
3 | III
Current consumption at 24 V
5 mA | 10 mA
Designation, Magnet control
IN
Designation, Safety outputs
Y1 and Y2
Leakage current Ir, maximum
0.5 mA
Nominal Çalışma Voltajı
24 VDC
ACE reference article number
193774
Switching frequency, maximum
1 Hz
Test pulse duration, maximum
5 ms | 1 ms
Test pulse interval, minimum
40 ms | 100 ms
Test pulse interval, typical
1 000 ms
Darbe Dayanım Gerilimi (Uimp)
0.8 kV
Fuse rating to UL 508, maximum
2 A
Classification ZVEI CB24I, Sink
C1 | C0
Designation, Diagnostic outputs
OUT
Length of sensor chain, maximum
200 m
Absicherung des Diagnoseausganges
short-circuit proof, p-type
Classification ZVEI CB24I, Source
C3 | C1 | C2
Depolama / Taşıma Sıcaklığı
-25 ... +75 °C | -25 ... +70 °C
Nominal Yalıtım Gerilimi (Uᵢ)
32 VDC
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical
100 mA
Number of digital fail-safe inputs
2
Assured switching distance "ON" Sao
0 mm
Current, Utilisation category DC-13
0.05 A | 0.25 A
Gerekli Nominal Kısa Devre Akımı
100 A
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Voltage, Utilisation category DC-13
24 VDC
Assured switching distance "OFF" Sar
1 mm
External wire and device fuse rating
2 A gG | 2 A gG (Connector M12, 8-pole)
Protection class (Operating resource)
3
Coding level according to EN ISO 14119
Low
Tightening torque of the fixing screws
8 Nm
Note (LED switching conditions display)
Error / functional defect: LED red | Operating condition: LED green | Supply voltage UB: LED green
Current consumption with magnet ON, peak
550 mA / 10 ms
Rated operating current (safety outputs)
250 mA
Storage and transport temperature, maximum
+70 °C
Storage and transport temperature, minimum
-25 °C
Current consumption with magnet ON, average
350 mA
Permissible installation altitude above sea level, maximum
2 000 m
Safety Integrity Level (SIL), suitable for applications in
3
Angular misalignment between solenoid interlock and actuator, maximum
2 °