RSS 36-D-R-ST-DU Emniyet Konum Şalterleri (PS Serisi)

RSS 36-D-R-ST-DU — Schmersal Emniyet Konum Şalterleri (PS Serisi). Başlıca özellikler: Çalışma Prensibi: RFID; Gövde Malzemesi: Glass-fibre, reinforced thermoplastic; IP Koruma Sınıfı: IP69 | IP67 | IP65; Ortam Sıcaklığı: -28 ... +70 °C; Sensör Uzunluğu: 22 mm. Ürün numarası: 103044826. Fiyat ve teslim süresi için teklif isteyebilirsiniz; teknik veriler ve belgeler aşağıdadır.

Ürün Açıklaması

  • • IP: IP65
  • • Ağırlık: 100 g
  • • Sertifika: cULus TÜV, cULus, ECOLAB, FCC, IC, ANATEL TÜV IC ECOLAB FCC

Standartlar

  • • EN IEC 60947-5-3
  • • EN IEC 61508
  • • EN ISO 13849-1
  • • EN IEC 62061

Ürün Özellikleri

  • • RFID teknolojisiyle evrensel kodlama
  • • 1 x M12 konnektör soketi, 8 kutuplu
  • • Actuation from side
  • • Thermoplastic enclosure
  • • 2 kısa devreye dayanıklı PNP güvenlik çıkışı
  • • Anahtarlama noktalarının yüksek tekrarlama doğruluğu
  • • RFID-technology for needs-based protection against tampering
  • • Yanlış hizalanmış çalıştırma mümkün
  • • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
  • • 27 mm x 108.2 mm x 35 mm

Teknik Özellikler

EPLAN Yes
PIN 1 1A1 Ue: (1)
PIN 2 X1 Safety input 1
PIN 3 A2 GND Mavi
PIN 4 Y1 Safety output 1 Black
PIN 5 OUT Diagnostic output OUT Grey
PIN 6 X2 Safety input 2 violet
PIN 7 Y2 Safety output 2 red
PIN 8 IN without function Pink
Coding Evrensel kodlama
Montaj A screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used.
CADENAS Yes
Kategori 4
Latching Yes
Genel Not Anforderungen an die Auswertung: Zweikanaliger Sicherheitseingang, geeignet für p-schaltende Sensoren mit Schließerfunktion. Die Funktionstests der Sensoren mit zyklischem Abschalten der Sensorausgänge für max. 1 ms müssen von der Auswertung toleriert wer
PFD value 2.10 x 10⁻⁵
PFH value 2.70 x 10⁻¹⁰ /h
Cascadable Yes
Traceparts Yes
Active area lateral
Kablo Kesiti 8 mm²
Voltage type DC
Darbe Dayanımı 30 g / 11 ms
Series-wiring Yes
Görev Süresi 20 Year(s)
Latching force 18 N
Net Ağırlık 100 g
Number of LEDs 3
Bağlantı Tipi Connector M12, 8-pole, A-coded
Connection type Cable (Y-UL 2517), 8-pole, Connector M12, 8-pole, Connector M12, 5-pole, A-coded
Sensor topology Sensor for series wiring
Actuating panels lateral
Brüt Ağırlık 100 g
Current derating Ambient temperature -25°C … +65°C: ≤ 0.25 A | Ambient temperature -25°C … +70°C: ≤ 0.1 A
Gövde Malzemesi Glass-fibre, reinforced thermoplastic
Protection class III
Safety functions Yes
Diagnostic output Yes
Kirlenme Derecesi 3
Operating voltage 24 VDC -15 % / +10 % (stabilised PELV power supply) | 24 VDC -15 % / +10 % (PELV to EN 60204-1)
Repeat accuracy R 0.5 mm
Scope of delivery Actuator must be ordered separately.
Sensör Uzunluğu 22 mm
Titreşim Dayanımı 10 … 55 Hz, genlik 1 mm
Wiring capacitance 50 nF
Çalışma Akımı 600 mA | 150 mA
Frequency band RFID 125 kHz
IP Koruma Sınıfı IP69 | IP67 | IP65
Ortam Sıcaklığı -28 ... +70 °C
Performans Seviyesi e
Sensör Genişliği 106.3 mm
Çalışma Prensibi RFID
Degree of protection IP65, IP67, IP69
Mekanik Ömür (min.) 1 000 000
Note (series-wiring) Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Sensör Yüksekliği 25 mm
Interfering radiation IEC 61000-6-4
Electrical fuse rating short-circuit proof
Reaction time, maximum 100 ms
Traceparts, product ID 69-13042011-105125
Cross-circuit detection Yes
Latching force, approx. 18 N
Short circuit detection Yes
Min. Ortam Sıcaklığı -28 °C
Note (Delivery capacity) Not available!
Note (Relative humidity) non-condensing | non-icing
Note (Repeat accuracy R) Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).Minimum clearance
Switch distance, typical 12 mm
Voltage drop Ud, maximum 2 V | 1 V
Duration of risk, maximum 200 ms
Housing construction form Block
Maks. Ortam Sıcaklığı +70 °C
Note (switching distance) All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator) RST 36-1 | RST 36-1-R
Type of the fixing screws 2x M4 (cylinder head screws with washers DIN 125A / form A)
Design of control elements short-circuit proof, p-type
Designation, Safety inputs X1 and X2
Kullanım Kategorisi DC-13 24 VDC / 0.25 A | 24_0.05
Mekanik Montaj Koşulları not flush
Note (Mechanical lifetime) Actuating speed < 0.25 m/s | Operations for door weights ≤ 5 kg
Operating current, minimum 0.5 mA
Operating voltage, maximum 26.4 VDC
Operating voltage, minimum 20.4 VDC
Relative humidity, maximum 93 %
Time to readiness, maximum 2 000 ms
Utilisation category DC-12 24 VDC / 0.25 A | 24 VDC / 0.05 A | 24_0.05 | 24_0.25
Aşırı Gerilim Kategorisi 3 | III
Designation, Safety outputs Y1 and Y2
Leakage current Ir, maximum 0.5 mA
Nominal Çalışma Voltajı 24 VDC −15 % / +10 % | 24 VDC
Switching frequency, maximum 1 Hz
Test pulse duration, maximum 0.3 ms | 1 ms
Test pulse interval, minimum 100 ms
Test pulse interval, typical 1 000 ms
Recommended safety switchgear SRB-E-301ST | SRB-E-201LC | PROTECT PSC1
Darbe Dayanım Gerilimi (Uimp) 0.8 kV
Classification ZVEI CB24I, Sink C1 | C2
Designation, Diagnostic outputs OUT
Electrical fuse rating, maximum 2 A
Rated operating voltage, maximum 26.4 VDC
Rated operating voltage, minimum 20.4 VDC
Transmitter output RFID, maximum -6 dBm
Absicherung des Diagnoseausganges short-circuit proof
Classification ZVEI CB24I, Source C1 | C2 | C3
Depolama / Taşıma Sıcaklığı -28 ... +85 °C
Nominal Yalıtım Gerilimi (Uᵢ) 32 VDC
Note (length of the sensor chain) Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical 35 mA
Assured switching distance "ON" Sao 10 mm
Current, Utilisation category DC-12 0.05 A | 0.25 A
Current, Utilisation category DC-13 0.05 A | 0.25 A
Gerekli Nominal Kısa Devre Akımı 100 A
Integral system diagnostics, status Yes
Number of fail-safe digital outputs 2
Voltage, Utilisation category DC-12 24 VDC
Voltage, Utilisation category DC-13 24 VDC
Absicherung des Sicherheitsausganges short-circuit proof
Assured switching distance "OFF" Sar 20 mm
Protection class (Operating resource) 3
Coding level according to EN ISO 14119 Low | I1 variant: HighI2 variant: HighStandard coded variant: Low
Tightening torque of the fixing screws 2.2 ... 2.5 Nm
Note (LED switching conditions display) LED green: Supply voltage | LED red: Fault | LED yellow: Operating condition
Current consumption of the safety inputs 5 mA
Hysteresis (Switching distance), maximum 2 mm
Rated operating current (safety outputs) 250 mA
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -28 °C
Output current, (fail-safe output), maximum 0.25 A
Tightening torque of the fixing screws, maximum 2.5 Nm
Tightening torque of the fixing screws, minimum 2.2 Nm
Number of semi-conductor outputs with signaling function 1
Permissible installation altitude above sea level, maximum 2 000 m
Safety Integrity Level (SIL), suitable for applications in 3
Reaction time, switching off safety outputs via actuator, maximum 100 ms
Reaction time, switching off safety outputs via safety inputs, maximum 0.5 ms

Aynı kategoriden diğer ürünler