EPLAN
Yes
Coding
Bireysel kodlama, çoklu öğretme (teach-in)
Montaj
2 x M5, Cylinder head screw
CADENAS
Yes
Kategori
4
PFD value
1.50 x 10⁻⁵
PFH value
6.30 x 10⁻¹¹ /h
Cascadable
Yes
Traceparts
Yes
Active area
front side | Glass-fibre, reinforced thermoplastic | cover-side | lateral
Kablo Kesiti
0.25 mm² ... 1.5 mm² | 0.25 mm² ... 1.5 mm² (All indications including the conductor ferrules.)
Voltage type
DC
Darbe Dayanımı
30 g / 11 ms
Kablo Girişi
M12 (A kodlaması)
Series-wiring
Yes
Görev Süresi
20 Year(s)
Net Ağırlık
195 g
Number of LEDs
2
Bağlantı Tipi
Connector M12, 8-pole
Latching magnet
Yes
Sensor topology
Sensor for series wiring
Actuating panels
from head | front side | rear
Brüt Ağırlık
195 g
Gövde Malzemesi
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Safety functions
Yes
Kirlenme Derecesi
3
Min. Kablo Kesiti
0.25 mm²
Operating voltage
24 VDC -15 % / +10 %
Operation current
150 mA
Repeat accuracy R
0.5 mm
Scope of delivery
Actuator must be ordered separately.
Sensör Uzunluğu
91 mm
Maks. Kablo Kesiti
1.5 mm²
Serial diagnostics
Yes
Wiring capacitance
50 nF
Çalışma Akımı
2 100 mA | 50 mA
IP Koruma Sınıfı
IP66 | IP67 | IP65
Ortam Sıcaklığı
-28 ... +70 °C
Performans Seviyesi
e
Sensör Genişliği
52 mm
Çalışma Prensibi
RFID
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Sensör Yüksekliği
30 mm
Switching thresholds
−3 V … 5 V (Low) | 15 V … 30 V (High)
Interfering radiation
IEC 61000-6-4
Reaction time, maximum
100 ms
Cross-circuit detection
Yes
Short circuit detection
Yes
Min. Ortam Sıcaklığı
-30 °C | -28 °C
Note (Relative humidity)
non-condensing | non-icing
Switch distance, typical
15 mm
Voltage drop Ud, maximum
2 V | 1 V
Duration of risk, maximum
200 ms
Housing construction form
Block
Maks. Ortam Sıcaklığı
+70 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator)
RST16-1-R
Design of control elements
short-circuit proof, p-type | p-type
Designation, Safety inputs
X1 and X2
Kullanım Kategorisi DC-13
24 VDC / 1 A | 24_0.05
Mekanik Montaj Koşulları
not flush
Operating current, minimum
0.5 mA
Relative humidity, maximum
93 %
Time to readiness, maximum
2 000 ms
Utilisation category DC-12
24_1 | 24 VDC / 0.05 A | 24 VDC / 1 A | 24_0.05
Aşırı Gerilim Kategorisi
3 | III
Leakage current Ir, maximum
0.5 mA
Nominal Çalışma Voltajı
24 VDC
Switching frequency, maximum
1 Hz
Test pulse duration, maximum
1 ms
Test pulse interval, minimum
100 ms
Recommended safety switchgear
PROTECT PSC1
Darbe Dayanım Gerilimi (Uimp)
0.8 kV
Classification ZVEI CB24I, Sink
C1
Rated operating voltage, maximum
26.4 VDC
Rated operating voltage, minimum
20.4 VDC
Absicherung des Diagnoseausganges
short-circuit proof, p-type
Classification ZVEI CB24I, Source
C1 | C2 | C3
Depolama / Taşıma Sıcaklığı
-28 ... +85 °C
Designation, Serial diagnostic SD
OUT
Nominal Yalıtım Gerilimi (Uᵢ)
32 VDC
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical
100 mA
Number of digital fail-safe inputs
2
Number of series-wiring of sensors
31
Assured switching distance "ON" Sao
5 mm
Current, Utilisation category DC-12
0.05 A | 1 A
Current, Utilisation category DC-13
1 A | 0.05 A
Gerekli Nominal Kısa Devre Akımı
100 A
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Voltage, Utilisation category DC-12
24 VDC
Voltage, Utilisation category DC-13
24 VDC
Absicherung des Sicherheitsausganges
short-circuit proof, p-type
Assured switching distance "OFF" Sar
30 mm
Coding level according to EN ISO 14119
High
Tightening torque of the fixing screws
2 Nm
Note (LED switching conditions display)
LED green: Supply voltage | Multi-coloured LED: Green, Red | LED red: Fault | LED yellow: Operating condition
Current consumption of the safety inputs
5 mA
Hysteresis (Switching distance), maximum
2 mm
Rated operating current (safety outputs)
1 000 mA
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-28 °C
Output current, (fail-safe output), maximum
1 A
Number of semi-conductor outputs with signaling function
1
Permissible installation altitude above sea level, maximum
2 000 m
Safety Integrity Level (SIL), suitable for applications in
3