EPLAN
Yes
Montaj
Screws
Notice
The SFB fulfils the requirements as PDDB (proximity switch with defined behaviour under fault conditions) according to EN 60947-5-3 in combination with magnetic sensors (2 NC contacts) up to PL e / SIL 3.
PFDavg
2.00 x 10⁻² | 8.80 x 10⁻³ | 2.60 x 10⁻⁴
CADENAS
Yes
Uzunluk
222.8 mm
Kategori
2 | 4
Adressing
Discovery and Configuration Protocol (DCP)
Genişlik
63 mm
PFH value
1.00 x 10⁻⁷ /h | 3.00 x 10⁻⁹ /h | 2.30 x 10⁻⁷ /h
LED colour
green/red | Yellow | Red | Green
LED status
Power-LED fieldbox | LED Activity Ethernet port | Input LED device port | System fault LED | BUS fault LED | Error LED device port | LED Link Ethernet port | Fieldbox error LED
Traceparts
Yes
Yükseklik
36.1 mm
LED position
"SF": Module | "BF": Module | L: P1 + P2 | "Err": Module | E: 0 ... 7 | A: P1 + P2 | I: 0 ... 7 | "Pwr": Module
Voltage type
DC
Darbe Dayanımı
30 g / 11 ms
Transfer rate
100 Mbit/s Full Duplex
Görev Süresi
20 Year(s)
Net Ağırlık
655 g
Bağlantı Tipi
M12 Connector socket/connector
Brüt Ağırlık
655 g
Gövde Malzemesi
Thermoplastic, Polyamide PA 6 GF
Protection class
III
Feldbus Protokoll
PROFINET / PROFIsafe
Fieldbus services
I&M0 ... I&M3, SNMP, LLDP
Integrated switch
Dual Port, 100 Mbit/s, IRT fähig
Kirlenme Derecesi
3
Operating voltage
24 VDC -15 % / +10 % (PELV to EN 60204-1) | 24 V
Service interface
WEB-Interface HTTP
Titreşim Dayanımı
10 … 150 Hz, genlik 0.35 mm / 5 g
Çalışma Akımı
10 000 mA
Current consumption
200 mA
Fieldbus properties
Media Redundancy Protocol (MRP) | Fast Start Up
IP Koruma Sınıfı
IP67 | IP65
Ortam Sıcaklığı
-25 ... +55 °C
Performans Seviyesi
e | d
Device Watchdog Time
10 ms
Switching thresholds
−3 V … 5 V (Low) | 15 V … 30 V (High)
Fieldbus specification
V2.3, Conformance Class C
Min. Ortam Sıcaklığı
-25 °C
Note (Delivery capacity)
Not available!
Note (Relative humidity)
non-condensing
Maks. Ortam Sıcaklığı
+55 °C
Type of the fixing screws
2x M6
Material of viewing window
Polyamide PACM 12
Relative humidity, maximum
95 %
Relative humidity, minimum
10 %
Time to readiness, maximum
8 000 ms
Aşırı Gerilim Kategorisi
III | 3
Fieldbus network load class
3
Nominal Çalışma Voltajı
24 VDC - 15 % / + 10 % (stabilised PELV) | 24 VDC
Material of the marking plate
Plastic, Polyamide PA
Note (application conditions)
Safe field box with decentralised I/Os
Specification safety fieldbus
V2.4
Terminal Connector, Field bus
M12, 4-pole, D-coded
Terminal Connector, Power I/O
M12 GÜÇ, 4 kutuplu, T kodlu
Darbe Dayanım Gerilimi (Uimp)
0.8 kV
Diagnostic Coverage (DC) Level
99 % | 90 %
Classification ZVEI CB24I, Sink
C1
Terminal connector, Input/Output
X0 - X7: M12, 8-pole, A-coded
Classification ZVEI CB24I, Source
C1 | C2 | C3
Depolama / Taşıma Sıcaklığı
-25 ... +70 °C | -25 ... +75 °C
Nominal Yalıtım Gerilimi (Uᵢ)
32 VDC
Test interval for error detection
adjusted F_WD_Time | 10 s
Note (Electrical data, Fuse rating)
external fuse protection required
Reaction Time Safety Input, maximum
20 ms
Device Acknowledgement Time, maximum
25 ms
Integral system diagnostics, general
Yes
Material of electronic encapsulation
Poliüretan 2K PU
Reaction Time Safety Output, maximum
50 ms
Protection class (Operating resource)
3
Storage and transport temperature, maximum
+70 °C
Storage and transport temperature, minimum
-25 °C
Tightening torque of electrical connection
1 Nm
Reaction time Fieldbus > local safety output
50 ms
Tightening torque of the fixing screws, maximum
3 Nm
Tightening torque of electrical connection, maximum
1.5 Nm
Response time of local safety input > Fieldbus, maximum
20 ms
Response time of local safety input ⇒ Fieldbus, maximum
20 ms
Permissible installation altitude above sea level, maximum
2 000 m
Safety Integrity Level (SIL), suitable for applications in
1 | 2 | 3