Kategori
2
Genel Not
Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA.
PFH value
3.59 x 10⁻⁷ /h
Görev Süresi
20 Year(s)
Net Ağırlık
4 900 g
Bağlantı Tipi
Connector
Length of cable
5 m
Number of beams
14
Brüt Ağırlık
4 900 g
Gövde Malzemesi
Aluminium
Protection class
III
Blanking function
Yes
Scope of delivery
Emitter + receiver, mounting angle
Diameter of sensor
60 mm
IP Koruma Sınıfı
IP65
Ortam Sıcaklığı
-10 ... +50 °C
Performans Seviyesi
d
Sensör Yüksekliği
1 129 mm
Tolerance, percentage
20 %
Reaction time, maximum
16 ms
Min. Ortam Sıcaklığı
-10 °C
Note (Delivery capacity)
Not available!
Maks. Ortam Sıcaklığı
+50 °C
Design of control elements
p-type
Integral system diagnostics
Yes
Recommended safety switchgear
SCR 211
Terminal connector, Recipient
Cable with connector plug M12, 8-pole
Wave length of the laserdiode
880 nm
Height of the protection field
1 075 mm
Range, protection field, maximum
6 m
Range, protection field, minimum
0.3 m
Restart interlock (manual reset)
Yes
Terminal, Connector, Transmitter
Cable with connector plug M12, 8-pole
Depolama / Taşıma Sıcaklığı
-20 ... +70 °C
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Switching voltage OSSD, HIGH signal
24 V
Protection class (Operating resource)
3
Length of the connectable cable, maximum
100 m
Safety type in accordance with IEC 61496-1
2
Storage and transport temperature, maximum
+70 °C
Storage and transport temperature, minimum
-20 °C
Output current, (fail-safe output), maximum
0.2 A
Electrical power consumption of the receiver
8 W
Electrical power consumption of the transmitter
4 W
Detection ability for test bodies at v = 1.6 m/s
80 mm
Safety Integrity Level (SIL), suitable for applications in
2