SLC 410-E/R0460-14-BM
Sipariş No 101186018
Sertifikalar TÜV
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Konum Şalterleri (PS Serisi)

SLC 410-E/R0460-14-BM Emniyet Konum Şalterleri (PS Serisi)

SLC 410-E/R0460-14-BM — Schmersal Emniyet Konum Şalterleri (PS Serisi). Başlıca özellikler: Gövde Malzemesi: Aluminium; IP Koruma Sınıfı: IP65; Ortam Sıcaklığı: +0 ... +55 °C; Sensör Uzunluğu: 35 mm; Sensör Genişliği: 45 mm. Ürün numarası: 101186018. Fiyat ve teslim süresi için teklif isteyebilirsiniz; teknik veriler ve belgeler aşağıdadır.

Ürün Açıklaması

  • • IP: IP65
  • • Sertifika: TÜV

Standartlar

  • • EN IEC 61496-1
  • • EN IEC 61496-2

Ürün Özellikleri

  • • NOTICE: Not available! (Replacement: SLC 420)
  • • Control Category 4

Teknik Özellikler

Genel Not The SLC 410 BM Master can be combined with all slaves of the SLC 410...RFS series.
Cascadable Yes
Bağlantı Tipi Connector
Number of beams 45
Gövde Malzemesi Aluminium
Protection class III
Blanking function Yes
Scope of delivery Emitter + receiver, mounting angle, T-slot nuts
Sensör Uzunluğu 35 mm
IP Koruma Sınıfı IP65
Ortam Sıcaklığı +0 ... +55 °C
Sensör Genişliği 45 mm
Sensör Yüksekliği 561 mm
Beam coding available Yes
Tolerance, percentage 20 %
Reaction time, maximum 13.5 ms
Min. Ortam Sıcaklığı +0 °C
Note (Delivery capacity) Not available!
Maks. Ortam Sıcaklığı +55 °C
Master- or Slave-function master
Design of control elements p-type
Integral system diagnostics Yes
Recommended safety switchgear SCR 402R-301
Terminal connector, Recipient Connector plug M12, 8-pole
Wave length of the laserdiode 950 nm
Height of the protection field 460 mm
Range, protection field, maximum 5 m
Range, protection field, minimum 0 m
Terminal, Connector, Transmitter Connector plug M12, 5-pole
Depolama / Taşıma Sıcaklığı -20 ... +70 °C
Integral system diagnostics, status Yes
Number of fail-safe digital outputs 2
Switching voltage OSSD, HIGH signal 24 V
Cable length (Master/Slave), maximum 50 m
Protection class (Operating resource) 3
Length of the connectable cable, maximum 100 m
Safety type in accordance with IEC 61496-1 4
Storage and transport temperature, maximum +70 °C
Storage and transport temperature, minimum -20 °C
Output current, (fail-safe output), maximum 0.5 A
Electrical power consumption of the receiver 3 W
Electrical power consumption of the transmitter 2 W
Detection ability for test bodies at v = 1.6 m/s 14 mm