Not
In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. | Reduction in range by 10% at an ambient temperature of -25°C | signal transmission in case of falling edge | The load inductance generates an induced voltage during the switch-off, which compromises the downstream components (sparkquenching element). | According to EN 61131-2
EPLAN
Yes
PIN 1
24 VDC power supply
PIN 2
0 VDC power supply | COD1 Coding 1
PIN 3
0 VDC power supply | Release S1 Input Release S1
PIN 4
COD2 Coding 2 | OSSD 1 Safety output 1
PIN 5
D_OUT Operating Mode
PIN 6
OSSD 2 Safety output 2
PIN 7
Muting operation: ML Muting lampCyclic mode: not used
PIN 8
Input Release S2
PIN 9
Muting operation: D_IN Input EDM, belt-stop, muting enableCyclic mode: D_IN Input EDM
PIN 10
Muting operation: MSG 2 Switching input muting sensor group MSG 2Cyclic mode: MK2 Machine contact 2
PIN 11
Not used
PIN 12
Muting operation: MSG 1 Switching input muting sensor group MSG 1Cyclic mode: MK1 Machine contact 1
CADENAS
Yes
Kategori
4
Override
Yes
PFH value
5.14 x 10⁻⁹ /h
Connection
Emitter | Receiver
LED status
OSSD ON, OSSD OFF, restart, signal reception, blanking, information | transmitting and status
Traceparts
Yes
LED position
Emitter | Receiver
Darbe Dayanımı
10 g, 16 ms, to EN 60028-2-29
Görev Süresi
20 Year(s)
Net Ağırlık
1 980 g
Bağlantı Tipi
Connector
Muting function
Yes
Number of beams
112
Brüt Ağırlık
1 980 g
Gövde Malzemesi
Aluminium
Protection class
III
7-segment display
Yes
Blanking function
Yes
Operating voltage
24 VDC -10 % / +10 % ((PELV) supply unit Imax 2.0 A, according to EN 60204 (power failure ≤ 20 ms))
Scope of delivery
Kit with 2 mounting angles
Sensör Uzunluğu
33 mm
Switching voltage
0 … 2 V (LOW) | 15 … 26.4 V (HIGH)
Titreşim Dayanımı
10 … 55 Hz
Reduced resolution
Yes
Current consumption
0 … 2 mA (LOW) | 3 … 10 mA (HIGH)
IP Koruma Sınıfı
IP67
Ortam Sıcaklığı
-25 ... +50 °C
Performans Seviyesi
e
Sensör Genişliği
27.8 mm
Switching thresholds
11 … 30 V (HIGH) | 0 … 2 V (LOW)
Beam coding available
Yes
Tolerance, percentage
10 %
Clock control possible
Yes
Load capacity, maximum
2.2 µF
Reaction time, maximum
20 ms
Terminal Bağlantısı
with metal thread
Note (Software Version)
as of 2024 Version 1.0
Rated operating current
250 mA
Load inductance, maximum
2 H
Min. Ortam Sıcaklığı
-25 °C
Designation, Power supply
ML
Maks. Ortam Sıcaklığı
+50 °C
Design of control elements
OSSD, short-circuit proof, p-type
Designation, Control inputs
S1, S2, MSG 1 and MSG 2
Designation, Safety outputs
OSSD 1 and OSSD 2
Integral system diagnostics
Yes
Leakage current Ir, maximum
1 mA
Nominal Çalışma Voltajı
24 VDC
ACE reference article number
11930047
Contactor control integrated
Yes
Test pulse duration, maximum
0.1 ms
Test pulse interval, typical
750 ms
Note (application conditions)
Automatic operation, restart inhibit, double confirmation, contactor control, object blanking (non-changeable position and changeable position), alternative beam coding, muting, cycle, multiple sampling
Recommended safety switchgear
SRB-E 301
Terminal connector, Recipient
Connector plug M12, 12-pole
Wave length of the laserdiode
880 nm
Conduction resistance, maximum
2.5 Ω
Height of the protection field
1 130 mm
Actuation time for manual start
50 … 1500 ms
Classification ZVEI CB24I, Sink
C1 | C3 | C2
Height of the Sensor (Receiver)
1 221 mm
Range, protection field, maximum
7 m
Range, protection field, minimum
0.3 m
Rated operating current, Emitter
200 mA
Restart interlock (manual reset)
Yes
Terminal, Connector, Transmitter
Connector plug M12, 4-pole
Classification ZVEI CB24I, Source
C3
Depolama / Taşıma Sıcaklığı
-25 ... +75 °C | -25 ... +70 °C
Rated operating current, Receiver
700 mA
Height of the Sensor (Transmitter)
1 211 mm
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Protection class (Operating resource)
3
Radiation emission level to EN 12198-1
Category 0
Length of the connectable cable, maximum
100 m
Safety type in accordance with IEC 61496-1
4
Storage and transport temperature, maximum
+70 °C
Storage and transport temperature, minimum
-25 °C
Output current, (fail-safe output), maximum
0.25 A
Reaction time of the external devices, maximum
500 ms
Detection ability for test bodies at v = 1.6 m/s
14 mm
Risk group classification of lamp systems to EN 62471
Serbest grup
Designation, Contactor controls EDM (Feedback circuits)
D_IN
Safety Integrity Level (SIL), suitable for applications in
3