Depth
121 mm
Montaj
Snaps onto standard DIN rail to EN 60715
Genel Not
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Genişlik
22.5 mm
EMC rating
EMC-Directive
Yükseklik
100 mm
Kablo Kesiti
0.25 mm² ... 2.5 mm²
Voltage type
DC
Darbe Dayanımı
10 g / 11 ms
Stop-Category
0
Görev Süresi
15 Year(s)
Net Ağırlık
264 g
Number of LEDs
5
Ripple voltage
10 %
Climatic stress
EN 60068-2-78
Brüt Ağırlık
264 g
Category, Stop 0
4
Gövde Malzemesi
Glass-fibre reinforced thermoplastic, ventilated
Kontak Malzemesi
AgSn0. kendi kendini temizleyen, pozitif tahrikli
Kirlenme Derecesi
2
Min. Kablo Kesiti
0.25 mm²
Operating voltage
24 VDC -10 % / +20 %
PFH value, Stop 0
2.00 x 10⁻⁸ /h
Titreşim Dayanımı
10 ... 55 Hz, Genlik 0.35 mm
Maks. Kablo Kesiti
2.5 mm²
Current consumption
57 mA
Ortam Sıcaklığı
-25 ... +60 °C | -30 ... +60 °C
Mekanik Ömür (min.)
10 000 000
Utilisation category
AC-15 | DC-13
Note (Wiring diagram)
Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range | The feedback circuit monitors the position of the contactors KA and KB. | To secure a guard door up to PL e and Category 4 | Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X2. If the feedback circuit is not required, establish a bridge. | If only one external relay or contactor is used to switch the load, the system can be classified in Control Category 3 to ISO 13849-1, if exclusion of the fault “Failure of the external contactor” can be substantiated and is documented, e.g. by using a re | The wiring diagram is shown with guard doors closed and in de-energised condition.
Terminal designations
IEC/EN 60947-1
Cross-circuit detection
Yes
Wire breakage detection
Yes
Automatic reset function
Yes
Min. Ortam Sıcaklığı
-25 °C
Güvenlik Kontak Sayısı
1
Maks. Ortam Sıcaklığı
+60 °C
Note (Contact resistance)
in new state
Earth connection detection
Yes
Explosion protection zones
2
Kullanım Kategorisi AC-15
2 A | 230 VAC
Kullanım Kategorisi DC-13
24 VDC | 2 A | 24 VDC / 2 A
Tightening torque of Clips
0.6 Nm
Yardımcı Kontak Sayısı
1
Aşırı Gerilim Kategorisi
III | 3
Contact resistance, maximum
0.1 Ω
Nominal Çalışma Voltajı
24 VDC -15%/+20%, residual ripple max. 10% | 24 VDC
Electrical power consumption
3 W
Explosion protection category
3G
Note (application conditions)
Pull-wire emergency stop switches | Emergency-Stop button | Safety sensor | Guard system
Conduction resistance, maximum
30 Ω
Darbe Dayanım Gerilimi (Uimp)
4 kV
Explosion protection designation
D II (2) D [Ex ib Db] IIIC | D II (2) G [Ex ib Gb] IIC | D II 3 G Ex nA nC IIC T5 Gc (Installation SRB, in Zone 2)
Performance Level, stop 0, up to
e
Depolama / Taşıma Sıcaklığı
-40 ... +85 °C
Explosion protection: regulations
EN IEC 60079-0 | EN 60079-11 | EN IEC 60079-15
Pull-in delay at RESET, typically
20 ms
Common Cause Failure (CCF), minimum
65
Integral system diagnostics, status
Yes
Rated control voltage at DC, maximum
28.8 VDC
NK (Normalde Kapalı) Kontak Sayısı
2
Diagnostic Coverage (DC) Level, Stop 0
≥ 99 %
IP Degree of protection of the enclosure
IP40
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-40 °C
Rated AC voltage for controls at DC minimum
20.4 VDC
IP Degree of protection of clips or terminals
IP20
IP Degree of protection of the installation space
IP54
Drop-out delay in case of power failure, typically
20 ms
Drop-out delay in case of "emergency stop", maximum
20 ms
Pull-in delay at automatic start, maximum, typically
300 ms
Safety Integrity Level (SIL), Stop 0, suitable for applications in
3