Depth
121 mm
Montaj
Snaps onto standard DIN rail to EN 60715
Genel Not
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Genişlik
45 mm
EMC rating
EMC-Directive
Yükseklik
100 mm
Start input
Yes
Kablo Kesiti
0.25 mm² ... 2.5 mm²
Voltage type
AC | DC
Darbe Dayanımı
30 g / 11 ms
Stop-Category
1 | 0
Görev Süresi
20 Year(s)
Net Ağırlık
360 g
Number of LEDs
7
Ripple voltage
10 %
Climatic stress
EN 60068-2-78
Electronic Fuse
Yes
Frequency range
50 Hz | 60 Hz
Brüt Ağırlık
360 g
Category, Stop 0
4
Category, Stop 1
3
Feedback circuit
Yes
Gövde Malzemesi
Glass-fibre reinforced thermoplastic, ventilated
Kontak Malzemesi
AgSn0. kendi kendini temizleyen, pozitif tahrikli
Kirlenme Derecesi
2
Min. Kablo Kesiti
0.25 mm²
Operating voltage
24 VAC -15 % / +10 %24 VDC -15 % / +20 %
PFH value, Stop 0
2.00 x 10⁻⁸ /h
PFH value, Stop 1
2.00 x 10⁻⁷ /h
Titreşim Dayanımı
10...55 Hz, Genlik 0.35 mm, ± %15
Maks. Kablo Kesiti
2.5 mm²
Çalışma Akımı
200 mA
Ortam Sıcaklığı
-25 ... +45 °C
Removable Terminals
Yes
Mekanik Ömür (min.)
10 000 000
Reset edge detection
Yes
Allowed type of cable
solid single-wire | flexible
Note (Wiring diagram)
For 2-channel control with cross-wire monitoring, connect the NC contact to S11/S12 and S31/S32 and bridge S21/S22 | F2 = Fuse for signalling outputs | For 1-channel control, connect NC contact to S11/S12 and bridge S21/S22 + S31/S32 | Early switch-off of time delay: The drop-out delay time can be ended early via the input RT. The input RT makes it possible to "switch off" the time-delayed enabling circuit 37/38 before the set time has elapsed." | The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix. | Input level: The example shows a 2-channel control of a guard door monitoring with two position switches, whereof one with positive break, external reset button (R) and feedback circuit (H2). (example without cross-wire monitoring) | Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. | Setting of the drop-out delay time is carried out by means of a potentiometer from the front of the enclosure. | "Start function / Reset button: The function "trailing edge" is programmed by means of the "AF" switch located underneath the housing cover (switch position = 1). The automatic start is programmed by bridging terminals X3/X5 and by switching the "AF" swit | F1 = Hybrid fuse | The control system recognises wire-breakage and earth faults in the monitoring circuit. | Connect potential p-type outputs of safety light grids/curtains to S12/S22. The devices must have the same reference potential. | Time delay: The time-delayed safety enable 37/38 is adjustable for 1 to 30 seconds drop-out delay (see setting intructions). | The wiring diagram is shown with guard doors closed and in de-energised condition.
Terminal designations
IEC/EN 60947-1
Terminal Bağlantısı
Screw terminals
Cross-circuit detection
Yes
Wire breakage detection
Yes
Automatic reset function
Yes
Min. Ortam Sıcaklığı
-25 °C
Note (Delivery capacity)
Not available!
Güvenlik Kontak Sayısı
3
Maks. Ortam Sıcaklığı
+45 °C
Note (Contact resistance)
in new state
Earth connection detection
Yes
Indicated operating states
Position relay K1 | Internal operating voltage Ui | Position relay K3 | Position relay K5 | Position relay K2
Tightening torque of Clips
0.6 Nm
Yardımcı Kontak Sayısı
1
Aşırı Gerilim Kategorisi
III | 3
Contact resistance, maximum
0.1 Ω
Nominal Çalışma Voltajı
24 VAC | 24 VDC | 24 VAC -15% / +10% | 24 VDC -15% / +20%, residual ripple max. 10 %
Electrical power consumption
5.2 VA | 4.4 W
Number of signalling outputs
8
Note (application conditions)
Safety light curtain | Pull-wire emergency stop switches | Emergency-Stop button | Safety sensor | Guard system
Conduction resistance, maximum
40 Ω
Darbe Dayanım Gerilimi (Uimp)
4 kV
Performance Level, stop 0, up to
e
Performance Level, stop 1, up to
d
Depolama / Taşıma Sıcaklığı
-40 ... +85 °C
Pull-in delay at RESET, typically
200 ms
Common Cause Failure (CCF), minimum
65
Integral system diagnostics, status
Yes
Rated control voltage at DC, maximum
28.8 VDC
NK (Normalde Kapalı) Kontak Sayısı
2
Diagnostic Coverage (DC) Level, Stop 0
≥ 99 %
Diagnostic Coverage (DC) Level, Stop 1
> 60 %
IP Degree of protection of the enclosure
IP40
Rated control voltage at AC 50 Hz, maximum
26.4 VAC
Rated control voltage at AC 60 Hz, maximum
26.4 VAC
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-40 °C
Rated AC voltage for controls at DC minimum
20.4 VDC
IP Degree of protection of clips or terminals
IP20
Rated AC voltage for controls, 50 Hz, minimum
20.4 VAC
Rated AC voltage for controls, 60 Hz, minimum
20.4 VAC
IP Degree of protection of the installation space
IP54
Drop-out delay in case of "emergency stop", maximum
15 ms
Pull-in delay at automatic start, maximum, typically
60 ms
Number of delayed semi-conductor outputs with signaling function.
1
Number of undelayed semi-conductor outputs with signaling function
7
Safety Integrity Level (SIL), Stop 0, suitable for applications in
3
Safety Integrity Level (SIL), Stop 1, suitable for applications in
2