Article No
11242295
Application Area
Industrial indoor environment
Nominal Gerinim
0 ... 500 μm/m
Baumer
Strain sensors
DST76-B500L Strain sensor
Baumer DST76-B500L features 25.4 mm x 10 mm x 89 mm dimensions, 4 x M6 screws mechanical mounting and < 0.2 % repeatability.
Technical Specifications
Article No
11242295
Application Area
Industrial indoor environment
Nominal Gerinim
0 ... 500 μm/m
Dimensions
25.4 mm x 10 mm x 89 mm
Product Description
- Measuring range ± 500 µm/m
- IO-Link interface for individual, application specific parameterisation
- Integrated amplifier electronics
- Output signal IO-Link with 2 x I/O
- Bore hole distance 76 mm
- Cable outlet
Detailed Technical Data
General Data
Dimensions
25.4 mm x 10 mm x 89 mm
Mechanical mounting
4 x M6 screws
Nominal gerinim
0 ... 500 μm/m
Repeatability
< 0.2 %
Non-linear deviation
< 0.4 %
IO-LINK INTERFACE
SIO-mode
Yes
Baud rate
230,4 kbaud (COM3)
Cycle time
≥ 1 ms
IO-Link port type
Class A
IO-Link version
1.1
Process data length
32 bit
Process data (cyclic)
- Process Value
- Scale exponent
- SSC 1
- SSC 2
- Quality
- Alarm
Mechanical Data
Weight
180 g
Overload
150 %
Sensor stiffness
2600 N @ 500 µm/m
Fatigue strength
>10 Mio cycles at 0...100% FS
Electrical Connection
Cable outlet, PUR cable, black Ø 3.2 mm, unshielded, oil-resistant, 4 x 0.14 mm2, open cable end, bending radius min. 10 x Ø, length 6 m
Material potting compound
Siliconfree, PUR based
Material sensor body
1.7225, chemically nickel plated
Compensated for thermal expansion coefficient
11.1 * 10-61/K
ENVIRONMENTAL CONDITIONS
Shock IEC 60068-2-27
50 g / 11 ms, 100 g / 6 ms
Random IEC 60068-2-64
20 ... 1000 Hz: 0.1 g²/Hz
Vibration IEC 60068-2-6
10 … 57 Hz: 1.5 mm p-p, 58 ... 2000 Hz: 10 g
Storage temperature range
-40 °C ... 85 °C
Protection class EN 60529, ISO20653
IP 65
Operating temperature range
-20 °C ... 70 °C
Electrical Data
Current consumption
≤ 40 mA
Bridge resistance
350 Ω
Supply voltage
18 VDC ... 30 VDC
Output Signal
IO-Link
Resolution ADC
24 bit
Resolution DAC
14 bit
Short-circuit protection
Yes
Cut-off frequency (3 db)
1000 Hz
Reverse polarity protection
Yes
Signal polaritesi pozitif
Tension
Sampling rate input
8 kS/s
COMPLIANCE AND APPROVALS
Conformity
- CE
- UL
IO-Link Features
Additional data
- Diagnostic data
- Error detection
Additional fonksiyonlar
- Low pass filter
- Peak value memory
- Sample and hold
- Two digital switching points (SSC)
- Remote operation
Parameterizable
- Unit (N, kg, µm/m) selectable
- Teach-in Offset/ Tare
- Correlation to known force
- Functions I/O's selectable
Documents
menu_book
Operating manual
PDF · Baumer_DAB10-Measuring-amplifier_IODD_Parameter_and_Process_Data_EN.pdf
open_in_new Open
electrical_services
EPLAN macro (EPLAN Data Portal)
WEB · dataportal.eplan.com/part-details/bau.11242295
open_in_new Open
settings_input_component
IODD
ZIP · Baumer-Force_Strain-L_ID60011-20220201-IODD1.1.zip