Article No
11731270
Dimension (flange)
ø105 mm, length 94 mm
Shaft Type
ø11 x 30 mm (keyed solid shaft)
Baumer
Heavy-duty incremental encoders
EHOG1060-S11200012 Incremental encoder
Baumer EHOG1060-S11200012 features ø100…160 mm size, straight shaft, 2048 … 3600 pulses, optical sensing method and IP 66 protection EN 60529.
Series: EHOG1060 / EHOG1070 — High-performant, incremental or redundant HeavyDuty encoders →
Technical Specifications
Article No
11731270
Dimension (flange)
ø105 mm, length 94 mm
Shaft Type
ø11 x 30 mm (keyed solid shaft)
Product Description
- Protection IP66, IP67
- Shaft insulation 3.5 kV
- Corrosion protection CX
- Operating temperature -40...+100 °C
- Signal outputs with automatic temperature compensation for stable signals up to 350 m (HTL-P)
- Sealed and user-friendly field termination
- Extended protection circuit
- 4-fold sealing concept for protection against abrasive dust, humid and salty moisture and temperature changes
- Cable gland M20
- Solid shaft ø11 mm
- Pulses per revolution 2048
Detailed Technical Data
Technical Data - Mechanical Design
Resistance
- IEC 60068-2-6
- Vibration 20 g, 10-2000 Hz
- IEC 60068-2-27
- Shock 300 g, 1 ms
- 1 Mio. brake shocks
Material
- Housing: aluminium, powder-coated
- Shaft: stainless steel
Shaft type
ø11 x 30 mm (switch-type flat mil)
Connection
Terminal box M20 with plug-in terminal block and cable gland
Mounting type
Solid shaft: EURO flange B10
Dimension (flange)
ø105 mm, length 94 mm
Starting torque
≤136 Ncm
Protection EN 60529
IP 66 / IP 67
Operating speed
≤6000 rpm (mechanical)
Corrosion protection
- IEC 60068-2-52 Salt mist
- for ambient conditions CX according to ISO 12944-2
Operating temperature
-40...+100 °C
Permissible shaft load
- ≤350 N axial
- ≤450 N radial
Rotor moment of inertia
300 gcm²
Technical Data - Electrical Values
Approval
- CE
- UL approval / E217823
- CSA
Phase shift
Typ. 90 °
Shaft isolation
Suitable up to 3.5 kV (DC)
Supply voltage
4.75...30 VDC (Vin = Vout, HTL/TTL)
Reference signal
Zero pulse, width 90° or 180°
Emitted interference
EN 61000-6-4
Consumption w/o load
≤100 mA
Duty cycle
Typ. 50 %
Transmission length
≤350 m at 100 kHz (HTL-P)
Detection method
Optical
Output stages
HTL-P (heavy-duty line driver)
Output signals
K1, K2, K0 + inverted
Interference immunity
EN 61000-6-2
Pulses per revolution
2048 (HTL-P)
Output frequency (typical)
≤200 kHz
Other pulses per revolution values
Pulse numbers parameterized ex works
Documents
build
Mounting instructions
PDF · Baumer_HOG1000-Vollwelle_EN_DE_FR_V1_MI_11733236.pdf
open_in_new Open
rocket_launch
Quick start guide
PDF · Baumer_EHOG1000-Vollwelle_EN_DE_FR_QS_11733236_V2.pdf
open_in_new Open
verified_user
Declaration of Conformity – CE
PDF · Baumer_EHOG10XX_ML_DoC_81458693.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval – MTTF
PDF · Reliability_Prediction_MTTF_D_1_09_BER_EHOG1060-xxxx000x2_EHOG1060-xxxPF00xx.pdf