Baumer EHOG840-E16200012
Article No 11730665
Dimension (flange) ø90 mm, length 72 mm
Shaft Type ø16 / G7 mm (blind hollow shaft)
Baumer Heavy-duty incremental encoders

EHOG840-E16200012 Incremental encoder

Baumer EHOG840-E16200012 features ø75…99 mm size, blind hollow shaft, 2048 … 3600 pulses, optical sensing method and IP 66 protection EN 60529.

Series: EHOG820 / EHOG840 — Economical, incremental HeavyDuty encoders →

Technical Specifications

Article No 11730665
Dimension (flange) ø90 mm, length 72 mm
Shaft Type ø16 / G7 mm (blind hollow shaft)
Product Description
  • Protection IP66
  • Shaft insulation 3.5 kV
  • Corrosion protection C4
  • Operating temperature -30...+85 °C
  • Cable length up to 200 m (HTL-P)
  • Sealed and user-friendly field termination
  • Blind hollow shaft ø16 mm
  • Pulses per revolution 2048

Detailed Technical Data

Technical Data - Mechanical Design

Resistance
  • IEC 60068-2-6
  • Vibration 20 g, 10-2000 Hz
  • IEC 60068-2-27
  • Shock 300 g, 1 ms
  • 1 Mio. brake shocks
Material
  • Body: aluminum
  • Shaft: stainless steel
Shaft type ø16G7 mm (blind hollow shaft)
Connection Terminal box M20 with plug-in terminal block and cable gland
Mounting type Hollow shaft: central screw
Dimension (flange) ø90 mm, length 72 mm
Starting torque ≤82 Ncm
Protection EN 60529 IP 66
Operating speed ≤6000 rpm (mechanical)
Corrosion protection
  • IEC 60068-2-52 Salt mist
  • for ambient conditions C4 according to ISO 12944-2
Operating temperature -30...+85 °C
Permissible shaft load
  • ≤350 N axial
  • ≤450 N radial
Rotor moment of inertia 120 gcm²

Technical Data - Electrical Values

Approval
  • CE
  • UL approval / E217823
  • CSA
Phase shift Typ. 90 °
Shaft isolation Suitable up to 3.5 kV (DC)
Supply voltage 4.75...30 VDC (Vin = Vout, HTL/TTL)
Reference signal Zero pulse, width 90° or 180°
Emitted interference EN 61000-6-4
Consumption w/o load ≤100 mA
Duty cycle Typ. 50 %
Transmission length ≤200 m at 100 kHz (HTL-P)
Detection method Optical
Output stages HTL-P (heavy-duty line driver)
Output signals K1, K2, K0 + inverted
Interference immunity EN 61000-6-2
Pulses per revolution 2048 (HTL-P)
Output frequency (typical) ≤200 kHz
Other pulses per revolution values Pulse numbers parameterized ex works

Documents

description Data sheet PDF · Baumer_EHOG840-E16200012_EN_20261026_DS.pdf open_in_new Open
build Mounting instructions PDF · Baumer_HOG800-Hohlwelle_EN_DE_FR_V1_MI_11730810.pdf open_in_new Open
build Mounting instructions PDF · Baumer_HOG800-Vollwelle_EN_DE_FR_V1_MI_11731129.pdf open_in_new Open
menu_book Operating manual PDF · Baumer_HOG800_EN_V2_MNL.pdf open_in_new Open
rocket_launch Quick start guide PDF · Baumer_EHOG800-Hohlwelle_EN_DE_FR_QS_11730810_V2.pdf open_in_new Open
menu_book Operating manual PDF · Baumer_EHOG800_EN_MNL_V4.pdf open_in_new Open
verified_user Declaration of Conformity – CE PDF · Baumer_EHOG8XX_ML_DoC_81449890.pdf open_in_new Open
verified Type Examination Certificate / Type approval – MTTF PDF · Reliability_Prediction_MTTF_D_1_09_BER_EHOG840-xxxxx0012.pdf open_in_new Open
verified_user Declaration of Conformity – CE PDF · Baumer_EHOG8XX_EN780_HS35_ML_DoC_81449890.pdf open_in_new Open
view_in_ar CAD data ZIP · Baumer_HOG840-Endwelle-1x-Kabelverschraubung-ohne-USB.stp_.zip open_in_new Open
electrical_services EPLAN macro (EPLAN Data Portal) WEB · dataportal.eplan.com/part-details/bau.11730665 open_in_new Open
table_chart Type code / ordering key PDF · HOG840-Typenschluesseltabelle_EN.pdf open_in_new Open
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3