Baumer FFDK 16P50Y5/0250
Article No 11178966
Measurement Technology Photoelectric leak sensor
Function Photoelectric leak sensor
Baumer Level sensors

FFDK 16P50Y5/0250 Photoelectric leak sensor

Baumer FFDK 16P50Y5/0250 features photoelectric leak sensor measuring technology, liquid level sensor and 940 nm wave length.

Series: Optical point level sensors →

Technical Specifications

Article No 11178966
Measurement Technology Photoelectric leak sensor
Function Photoelectric leak sensor
Features Pulsed infrared diode / PNPCable 3 pin, 2,5 m-10 … 55 °CIP 50
Product Description
  • liquid level sensor
  • 3 … 7 mm
  • pulsed infrared diode
  • PNP
  • no
  • cable 3 pin, 2.5 m
  • -10 … 55 °C
  • IP 50

Detailed Technical Data

General Data

Type Liquid level sensor
Wavelength 940 nm
Light source Pulsed infrared diode
Sensitivity setting No
Output indicator Red LED
Max. pipe/tube outer diameter 3 … 7 mm
Max. pipe/tube wall thickness 1 mm

Mechanical Data

Depth 26 mm
Design Rectangle
Width / diameter 16 mm
Housing material PC
Connection types 3-pin cable, 2.5 m
Height / length 28 mm

Ambient conditions

Protection class IP 50
Operating temperature -10 … +55 °C

Electrical Data

Output current 100 mA
Output circuit PNP
Output function In light / in the dark operating, selectable
Short-circuit protection Yes
Voltage drop Vd <1 VDC
Reverse polarity protection Yes
Supply voltage range +Vs 10 … 30 VDC
Max. current consumption (no load) 25 mA
Response time / release time < 2 ms

Documents

description Data sheet PDF · Baumer_FFDK-16P50Y5-0250_EN_20260615_DS.pdf open_in_new Open
menu_book Operating manual PDF · m_ffdk16p50y50250.pdf open_in_new Open
verified_user Declaration of Conformity – CE PDF · Baumer_Fxxx_16_ML_DoC_81234563.pdf open_in_new Open
view_in_ar CAD data ZIP · FFDK_16P50Y5.stp.zip open_in_new Open
electrical_services EPLAN macro (EPLAN Data Portal) WEB · dataportal.eplan.com/part-details/bau.11178966 open_in_new Open
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3