Article No
11197904
Baumer
Flow measurement
FlexFlow PF20H-11.010.C046.20.0.0000.0 Flow sensor
Baumer FlexFlow PF20H-11.010.C046.20.0.0000.0 features digital (push-pull) output type, 30 g / 11 ms, 6 jolts per axis and direction shock, IP67 / IP68 , 30 min. @ 1 mH2O / IP69K , with appropriate cable degree of protection and 5 g (10 ... 2000 Hz) vibration.
Technical Specifications
Article No
11197904
Product Description
- SIP- capable without restrictions up to 150 °C / 24h
- Broad portfolio of process connections
- Flow and temperature measurement in a single sensor
- Compact and robust
- Available with IO-Link interface
Detailed Technical Data
PROCESS CONDITIONS
Process temperature
- -25 … 125 °C , flow measurement
- -25 … 150 °C , temperature measurement @ flow > 0 cm/s
Ambient conditions
Shock (EN 60068-2-27)
30 g / 11 ms, 6 jolts per axis and direction
Protection degree (EN 60529)
- IP67
- IP68 , 30 min. @ 1 mH2O
- IP69K , with appropriate cable
Vibration (sinusoidal) (EN 60068-2-6)
5 g (10 ... 2000 Hz)
Output signal
Current output
4 … 20 mA
Process connection
Process Connection
ISO 2852 (Tri-Clamp), DN 25; 33.7; 38, Ø 50.5 (C04)
Wetted parts material
AISI 316L (1.4404)
Surface roughness wetted parts
Ra ≤ 0.8 µm
COMPLIANCE AND APPROVALS
Hygiene
- FDA compliant
- EHEDG EL Class I
Performance characteristics
Step response time
< 5 s
Max. measurement error
- ± 2 % FSR , flow measurement
- ± 8 cm/s , flow measurement
- ± 1 °C , temperature measurement @ flow > 0 cm/s
Measuring range, flow
10 … 400 cm/s
Measuring range, temperature
-25 … 150 °C
Down time at temperature step
< 10 s
Documents
rocket_launch
Quick start guide
PDF · Baumer_PF20S-1_PF20H-1_QS_EN_DE_FR_IT_ES_PL_RU.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval
PDF · Baumer_PF20_UL_certificate_E469449.pdf
open_in_new Open
electrical_services
EPLAN macro (EPLAN Data Portal)
WEB · dataportal.eplan.com/part-details/bau.11197904
open_in_new Open