Article No
11039873
Measurement Range
-100...1820°C
Baumer
Temperature measurement
FlexTop 2203-0001.0 Temperature transmitter
Baumer FlexTop 2203-0001.0 features 4 … 20 mA output type and -100...1820°C measuring range.
Series: T/C-temperature transmitters with 4 … 20 mA output →
Technical Specifications
Article No
11039873
Measurement Range
-100...1820°C
Product Description
- Specifically for T/C
- Input: T/C, mV
- Measuring range -100 ... +1820 °C
- More accurate than 5 °C
- ATEX explosion protection
- DIN form B housing installation
Detailed Technical Data
Ambient conditions
Humidity
< 98 % RH , condensing
Protection degree (EN 60529)
IP 40
Long-term test (transmitter)
IEC 770 6.3.2
Vibration (sinusoidal) (EN 60068-2-6)
1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
Output signal
TAG No.
15 characters
Accuracy
< 0.1 % FSR
Damping
0.0 … 30 s , programmable
Load resistance
R = (U - 8 V)/23 mA
Power Supply
8 … 35 V DC
Resolution
12 bit
Output Signal
4 … 20 mA, 2 wire
Temperature drift
- < 0.003 %/K , typ.
- < 0.01 %/K , max.
Reverse polarity protection
Yes
Power-on time
≤ 10 s
Up/Down scaling limits
23 mA / 3.5 mA
Effect of supply voltage ripple
< 0.01 %/V
Ripple immunity
3 Vrms
COMPLIANCE AND APPROVALS
EMC
- EN 61000-6-2
- EN 61000-6-3
- EN 61326-1
Namur
NE21
Documents
verified_user
Declaration of Conformity – CE
PDF · Baumer_Flextop-220x_ML_DoC_81204307.pdf
open_in_new Open
article
Technical Reports / White Paper
PDF · Baumer_Analog_Sensor_Interfaces_Guideline_V1.00_EN.pdf
open_in_new Open
article
Technical Reports / White Paper
PDF · Baumer_Explosion_Protection_Guideline_(ATEX)_V1.40_EN.pdf
open_in_new Open
article
Technical Reports / White Paper
PDF · Baumer_Definitions of Sensor Properties_V1.1_EN.pdf
open_in_new Open