Baumer FlexTop 2222-0001.0
Article No 11210035
Measurement Range -200...1820°C
Baumer Temperature measurement

FlexTop 2222-0001.0 Temperature transmitter

Baumer FlexTop 2222-0001.0 features 4 … 20 mA output type and -200...1820°C measuring range.

Series: Universal in-head transmitter with HART protocol for CombiTemp or OEM applications →

Technical Specifications

Article No 11210035
Measurement Range -200...1820°C
Product Description
  • Universal transmitter with HART® communication
  • Programmable through integrated USB port or HART® modem
  • Sensor calibration for either offset, slope or polynomial adjustment
  • Accuracy better than 0.1°C for RTD elements
  • Automatic cable compensation calibration (2-wire)
  • Fast sampling time < 50 ms
  • Galvanic isolated
  • ATEX and IECEx certified

Detailed Technical Data

HART® Interface

Protocol
  • HCF standard, Rev.7
  • including „Temperature Device Family“ commands
Features
  • Read serial number
  • Read/Change user ID
  • Read/Change configuration
  • Read input signal value
  • Read output signal value
  • Input signal logging
  • 2-point sensor-trim
  • For more information please see ‚HART Field Device Specification‘

Ambient conditions

Humidity < 98 % RH , condensing
Insulation voltage 1.5 kV AC
Protection degree (EN 60529) IP 55

Output signal

Accuracy < 0.025 % FSR
Damping 0 … 60 s
Load resistance Rs ≤ (V DC - 7 V)/0.023 A
Characteristic Linear or customised with max. 30 points
Resolution 14 bit
Output Signal
  • 4 … 20 mA, 2 wire
  • 20 … 4 mA , 2-wire
Temperature drift ± 0.01 %/K , max.
Step response time, T90 < 450 ms
Up/Down scaling limits 23 mA / 3.5 mA
Effect of supply voltage ripple 0.001 %/V
Ripple immunity < 1 % FSR (1 Vrms, 50Hz...1kHz)

COMPLIANCE AND APPROVALS

EMC
  • EN 61326-1
  • DNV GL - Class A
  • EN 50121-3-2:2016
Namur NE21

Documents

description Data sheet PDF · Baumer_2222_EN_20260217_DS.pdf open_in_new Open
menu_book Operating manual PDF · Baumer_FlexTop_22x2_MA_EN_DE_FR_11202169_06.pdf open_in_new Open
menu_book Operating manual PDF · 81311378_HART_Field_Device_Specification_for_2222.pdf open_in_new Open
verified_user Declaration of Conformity – CE PDF · Baumer_Flextop-22122222_ML_DoC_81299898.pdf open_in_new Open
eco China RoHS declaration PDF · Baumer_BADK_China_RoHS_CN-EN_SD_81406578.pdf open_in_new Open
view_in_ar CAD data STP · 2222-000x.x.stp open_in_new Open
settings_input_component Device description file (EDS/GSD/ESI/…) ZIP · Baumer_FlexTop_2222_DDL_01.zip open_in_new Open
memory Firmware ZIP · FlexTop_2222_04-00-05.zip open_in_new Open
download Software ZIP · FlexProgram software package C-08-01.zip open_in_new Open
download Software ZIP · Baumer_BssSetup_1.9.4.0_public.msi.zip open_in_new Open
download Software ZIP · Baumer_BssSetup_1.12.0.0_public.msi.zip open_in_new Open
article Technical Reports / White Paper PDF · Baumer_Analog_Sensor_Interfaces_Guideline_V1.00_EN.pdf open_in_new Open
article Technical Reports / White Paper PDF · Baumer_Definitions of Sensor Properties_V1.1_EN.pdf open_in_new Open
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3