Article No
11729167
Measurement Range
0...360°
Resolution
1 … 0.001 °
Baumer
Static tilt sensors
GIM600R-N136.SC6.A Tilt sensor
Baumer GIM600R-N136.SC6.A features IP 66 / IP 67 / IP 68 / IP 69K protection EN 60529, CANopen® interface, typical ±0.1° accuracy, connector connection and 1 dimensional model.
Series: GIM600R — 1-dimensional inclination sensor, vertical installation →
Technical Specifications
Article No
11729167
Measurement Range
0...360°
Resolution
1 … 0.001 °
Accuracy (+25 °C)
Tip. ±0.1°
Product Description
- Designed for Mobile Maschines
- E1 compliant design
- Load dump protection
- Protection up to IP 69K
- Corrosion protection CX (C5-M)
- Connection cable / cable with M12 connector
- Interface CANopen®
- Applicable up to PLd (ISO 13849)
Detailed Technical Data
Technical Data - Mechanical Design
Resistance
- EN 60068-2-6
- Vibration 30 g, 60-2000 Hz
- EN 60068-2-27
- Shock 200 g, 3 ms
- EN 60068-2-64
- Random vibration 10 gRMS, 20-1000 Hz
Material
- Housing: polyamide (glass fiber reinforced)
- Base plate: metal
Connection
Braided cable connector M12, 5-pin, length 300 mm
Protection EN 60529
- IP 66
- IP 67
- IP 68 (without connector)
- IP 69K (without connector)
Dimensions W x H x L
72 x 24 x 64 mm
Corrosion protection
- IEC 60068-2-52 Salt mist
- for ambient conditions CX (C5-M) according to ISO 12944-2
Approximate weight
150 g
Operating temperature
-40...+85 °C (see general information)
Temperature changes
EN 60068-2-14, -40…+85 °C
Technical Data - Electrical Values
Approval
UL approval / E217823
Interface
CANopen®
Resolution
1 … 0.001 °
Detection speed
1000 Hz (1 ms)
Supply voltage
8...36 VDC
Consumption (typical)
- 15 mA (24 VDC, w/o load)
- 30 mA (24 VDC, w/o load, redundant)
Emitted interference
- EN 61000-6-3
- EN 61000-6-4
- ISO 7637-2*
- CISPR 25:2008 (30...1000 MHz)
- * Severity level according to ECE R10 (Rev. 6 + Amd 02:2021-12)
MTTFd (ISO 13849)
- High (>100 years)
- Use in safety functions exclusively based on quick start guide, Application Note and MTTFd reliability prediction (request separately).
Detection method
MEMS technology
Diagnostic function
- Supply voltage monitoring
- Temperature control
Output stages
CAN-Bus compatible ISO 11898
Accuracy (+25 °C)
Typical ±0.1°
Limit frequency
0.1...30 Hz, 2. order / low-pass filter
Load dump protection
- ISO 16750-2 for 12 V / 24 V systems
- Pulse 5b (test criteria B)
Measuring range
0...360°
Short-circuit protected
Yes
Max. absolute accuracy
- ±0.26° (+25 °C)
- ±0.47° (0…+50 °C)
- (measuring range 0…360°, see general information)
Reverse polarity protection
Yes
Start-up time (typical)
power after power on ≤ 1 sn
Interference immunity
- EN 61000-6-2
- ISO 7637-2*
- ISO 7637-3*
- ISO 11452-2*
- ISO 11452-4*
- ISO 11452-5*
- EN 61000-4-2 (CD ±8 kV, AD ±15 kV)
- * Severity level according to ECE R10 (Rev. 6 + Amd 02:2021-12)
Repeatability (typical)
0.025 ° (+25 °C)
Programmable parameters
- Preset / zero position
- Resolution
- Limit frequency (low-pass filter)
- Rotating direction
Documents
rocket_launch
Quick start guide
PDF · Baumer_GIM600-1-dim_DE_EN_FR_QS_V5_81447354.pdf
open_in_new Open
verified_user
Declaration of Conformity – CE
PDF · Baumer_GIM600R_ML_DoC_81447069.pdf
open_in_new Open