Baumer GIM600R-N290.PC6.A
Article No 11729164
Measurement Range ±90°
Resolution 1 … 0.001 °
Baumer Static tilt sensors

GIM600R-N290.PC6.A Tilt sensor

Baumer GIM600R-N290.PC6.A features IP 66 / IP 67 / IP 68 / IP 69K protection EN 60529, CANopen® interface, typical ±0.1° accuracy, connector connection and 2 dimensional model.

Series: GIM600R — 2-dimensional inclination sensor, horizontal installation →

Technical Specifications

Article No 11729164
Measurement Range ±90°
Resolution 1 … 0.001 °
Accuracy (+25 °C) Tip. ±0.1°
Product Description
  • Designed for Mobile Maschines
  • E1 compliant design
  • Load dump protection
  • Protection up to IP 69K
  • Corrosion protection CX (C5-M)
  • Cable with 2xM12 connector
  • Interface CANopen®
  • 1-channel version
  • Applicable up to PLd (ISO 13849)

Detailed Technical Data

Technical Data - Mechanical Design

Resistance
  • EN 60068-2-6
  • Vibration 30 g, 60-2000 Hz
  • EN 60068-2-27
  • Shock 200 g, 3 ms
  • EN 60068-2-64
  • Random vibration 10 gRMS, 20-1000 Hz
Material
  • Housing: polyamide (glass fiber reinforced)
  • Base plate: metal
Connection Pre-assembled connector 2xM12, 5-pin, (Bus-in/Bus-out), length 300 mm
Protection EN 60529
  • IP 66
  • IP 67
  • IP 68 (without connector)
  • IP 69K (without connector)
Dimensions W x H x L 72 x 24 x 64 mm
Corrosion protection
  • IEC 60068-2-52 Salt mist
  • for ambient conditions CX (C5-M) according to ISO 12944-2
Approximate weight 150 g
Operating temperature -40...+85 °C (see general information)
Temperature changes EN 60068-2-14, -40…+85 °C

Technical Data - Electrical Values

Approval UL approval / E217823
Interface CANopen®
Resolution 1 … 0.001 °
Detection speed 1000 Hz (1 ms)
Supply voltage 8...36 VDC
Consumption (typical)
  • 15 mA (24 VDC, w/o load)
  • 30 mA (24 VDC, w/o load, redundant)
Emitted interference
  • EN 61000-6-3
  • EN 61000-6-4
  • ISO 7637-2*
  • CISPR 25:2008 (30...1000 MHz)
  • * Severity level according to ECE R10 (Rev. 6 + Amd 02:2021-12)
MTTFd (ISO 13849)
  • High (>100 years)
  • Use in safety functions exclusively based on quick start guide, Application Note and MTTFd reliability prediction (request separately).
Detection method MEMS technology
Diagnostic function
  • Supply voltage monitoring
  • Temperature control
Output stages CAN-Bus compatible ISO 11898
Accuracy (+25 °C) Typical ±0.1°
Limit frequency 0.1...30 Hz, 2. order / low-pass filter
Load dump protection
  • ISO 16750-2 for 12 V / 24 V systems
  • Pulse 5b (test criteria B)
Measuring range ±90°
Short-circuit protected Yes
Reverse polarity protection Yes
Start-up time (typical) power after power on ≤ 1 sn
Interference immunity
  • EN 61000-6-2
  • ISO 7637-2*
  • ISO 7637-3*
  • ISO 11452-2*
  • ISO 11452-4*
  • ISO 11452-5*
  • EN 61000-4-2 (CD ±8 kV, AD ±15 kV)
  • * Severity level according to ECE R10 (Rev. 6 + Amd 02:2021-12)
Repeatability (typical) 0.025 ° (+25 °C)
Programmable parameters
  • Preset / zero position
  • Resolution
  • Limit frequency (low-pass filter)
  • Rotating direction
Max. absolute accuracy (vertical)
  • ±0.47° (+25 °C)
  • ±0.86° (0…+50 °C)
  • (measuring range ±10°, see general information)
Max. absolute accuracy (horizontal)
  • ±0.24° (+25 °C)
  • ±0.41° (0…+50 °C)
  • (measuring range ±10°, see general information)
Max. cross-axis sensitivity (+25 °C)
  • ±0.23° (2-dimensional horizontal)
  • ±0.47° (2-dimensional vertical)
  • Measuring range ±10°

Documents

description Data sheet PDF · Baumer_GIM600R-N290.PC6_.A_EN_20251209_DS.pdf open_in_new Open
build Mounting instructions PDF · Baumer_GIM600R-2-dim_DE_EN_FR_V3_MI_81447355.pdf open_in_new Open
rocket_launch Quick start guide PDF · Baumer_GIM600-2-dim_DE_EN_FR_QS_V5_81447355.pdf open_in_new Open
verified_user Declaration of Conformity – CE PDF · Baumer_GIM600R_ML_DoC_81447069.pdf open_in_new Open
view_in_ar CAD data ZIP · Baumer_GIM600R_2xM12_5Pin_Bus-in-out.stp_CAD.zip open_in_new Open