Housing
0.01 ° (configurable, Default: 0.1°)
Sensing Range
CANopen®; SAE J1939
Baumer
Dynamic tilt sensors
GIM700DR - 2-dimensional
Dynamic tilt sensor
Technical Specifications
Housing
0.01 ° (configurable, Default: 0.1°)
Sensing Range
- CANopen®
- SAE J1939
Features
- High measurement accuracy in dynamic applications
- Rugged housing for harsh environments
- Interfaces: CANopen®, SAE J1939
- Connections: 2 x M12
- E1-compliant design
- Protection rating up to IP 69K
- Corrosion protection: CX (C5-M)
Detailed Technical Data
TEKNIK VERILER - MEKANIK TASARIM
Resistance
EN 60068-2-6Vibration 20 g, 60-2000 HzEN 60068-2-27Shock 200 g, 6 ms
Material
Housing: poliamid (glass elyaf takviyeli), Aluminium coated
Connection
Flange connector M12, 5-pin
Protection EN 60529
IP 67IP 68IP 69K (ISO 20653)
Corrosion protection
EN 60068-2-52 Salt mistfor ortam conditions CX (C5-M) in accordance with ISO 12944-2
Temperature changes
EN 60068-2-14, -40…+85 °C, 5 döngü
Dimensions W x H x L
77 x 62 x 27 mm
Approximate weight
134 g
Operating temperature
-40...+85 °C (see general information)
TECHNICAL DATA - ELECTRICAL RATINGS
Approval
CE
Interface
CANopen®SAE J1939
Limit frequency
1...30 Hz / low passing filtre up to 6th order (configurable, gyroscope also bandpass)
Resolution
0.01 ° (configurable, Default: 0.1°)
Detection speed
100 Hz
Supply voltage
8...36 VDC
Load dump protection
ISO 16750-2 for 12 V/24 V systemsPulse 5b (test criteria A)
Emitted interference
EN 61000-6-4CISPR 25:2008 (30...1000 MHz)ISO 7637-2:2004** Severity level according to ECE R10 (Rev. 5)
Start-up time
power after power on ≤ 1 sn
Measuring range
±90° (inclination sensor, ±180° on on request)±6 g (accelerometer, triaxial)±250°/s (gyroscope, triaxial, Z-axis 125°/s)
Consumption w/o load
≤30 mA (24 VDC)
Short-circuit protected
Yes
Temperature coefficient
Typ. ≤± 0.01 °/K (zero position)
Reverse polarity protection
Yes
Statik accuracy (typical)
±0.3° (+25 °C)
Dinamik accuracy (typical)
±0.5° (see general information)
Interference immunity
EN 61000-6-2ISO 11452-2:2004*ISO 7637-2:2004*ISO 10605:2008 + Amd 1:2014 (CD ±8 kV / AD ±15 kV)* Severity level according to ECE R10 (Rev. 5)