Baumer HOG 10 G
Shaft Type ø105 mm
Baumer Bearingless encoders

HOG 10 G Incremental encoder - combination

Baumer HOG 10 G features ø100…160 mm size, blind hollow shaft, 3601 … 5000 pulses, optical sensing method and IP 66 protection EN 60529.

Series: HOG10 / POG10 — The unrivalled benchmark →

Technical Specifications

Shaft Type ø105 mm
Product Description
  • Twin encoder featuring two separate systems
  • TTL output driver for cable length up to 550 m
  • Very high resistance to shock and vibrations
  • Hybrid bearing for extended service life
  • Large terminal boxes, turn by 180°

Detailed Technical Data

Technical Data - Mechanical Design

Resistance
  • IEC 60068-2-6
  • Vibration 20 g, 10-2000 Hz
  • IEC 60068-2-27
  • Shock 300 g, 6 ms
Material
  • Housing: aluminium die-cast
  • Shaft: stainless steel
Shaft type
  • ø16...20 mm (blind hollow shaft)
  • ø17 mm (conical shaft 1:10)
Connection
  • 2x terminal box
  • 4x terminal box (with option M)
Dimension (flange) ø105 mm
Protection EN 60529 IP 66
Operating speed ≤6000 rpm (mechanical)
Corrosion protection
  • IEC 60068-2-52 Salt mist
  • for ambient conditions C4 according to ISO 12944-2
Approximate weight
  • 2.9 kg
  • 3.3 kg (with option M)
Explosion protection
  • II 3 G Ex ec IIC T4 Gc (gas)
  • II 3 D Ex tc IIIC T135°C Dc (dust)
  • (only with option ATEX)
Operating temperature
  • -40...+100 °C
  • -25...+100 °C (>3072 pulses)
Operating torque (typical) 6 Ncm
Permissible shaft load
  • ≤450 N axial
  • ≤600 N radial
Rotor moment of inertia 340 gcm²

Technical Data - Electrical Values

Approval
  • CE
  • UL approval / E217823
Phase shift 90 ° ±20°
Shaft isolation Suitable up to 2.8 kV
Supply voltage
  • 9...30 VDC
  • 5 VDC ±5 %
Reference signal Zero pulse, width 90°
Emitted interference EN 61000-6-3
Consumption w/o load ≤100 mA
Duty cycle 40…60 %
Transmission length
  • ≤350 m at 100 kHz (HTL-P)
  • ≤550 m at 100 kHz (TTL)
Detection method Optical
Output stages
  • HTL-P (heavy-duty line driver)
  • TTL/RS422
Output frequency
  • ≤120 kHz
  • ≤300 kHz (on request)
Output signals
  • K1, K2, K0 + inverted
  • Error output (option EMS)
Interference immunity EN 61000-6-2
Pulses per revolution 300 … 5000

Documents

description Data sheet PDF · Baumer_HOG-10-G_EN_20251117_DS.pdf open_in_new Open
build Mounting instructions PDF · Baumer_HOG10-HOG10G_T2_DE_EN_202403_MI_11068772.pdf open_in_new Open
build Mounting instructions PDF · Baumer_HOG10-HOG10G-CANNON_T1_DE_EN_202209_MI_11145663.pdf open_in_new Open
build Mounting instructions PDF · Baumer_HOG10-HOG10G-Harting_T1_DE_EN_202209_MI_11145664.pdf open_in_new Open
build Mounting instructions PDF · Baumer_HOG10-HOG10G-FC_DE_EN_202403_MI_11068613.pdf open_in_new Open
verified_user Declaration of Conformity – CE PDF · Baumer_Encoder_Size_10_ML_DoC_81376584.pdf open_in_new Open
verified_user Declaration of Conformity – CE PDF · Baumer_Encoder_ERD_ML_DoC_81376669.pdf open_in_new Open
view_in_ar CAD data ZIP · Baumer_HOG10G_CAD.zip open_in_new Open
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3