Dimension (flange)
> ø90 mm
Shaft Type
Output stages / HTL/power linedriver / TTL/RS422
Baumer
Industrial absolute encoders
HOG 10 - stainless steel Incremental encoder
Baumer HOG 10 - stainless steel features ø100…160 mm size, closed-end hollow shaft, 3601 … 5000 pulses, optical sensing method and IP 66 protection EN 60529.
Technical Specifications
Dimension (flange)
> ø90 mm
Shaft Type
Output stages / HTL/power linedriver / TTL/RS422
Number of steps per revolution
ø16 mm (blind hollow shaft)ø17 mm (tapered shaft 1:10)
Product Description
- Housing made of stainless steel
- TTL output driver for cable length up to 550 m
- Very high resistance to shock and vibrations
- Hybrid bearing for extended service life
Detailed Technical Data
Technical Data - Mechanical Design
Resistance
- IEC 60068-2-6
- Vibration 15 g, 10-2000 Hz
- IEC 60068-2-27
- Shock 200 g, 6 ms
Material
- Housing: stainless steel
- Shaft: stainless steel
Shaft type
- ø16 mm (blind recessed mil)
- ø17 mm (conical shaft 1:10)
Connection
- Cable HEK 8
- Cable ÖLFLEX 2 m
- Terminal box
Dimension (flange)
ø105 mm
Protection EN 60529
IP 66
Operating speed
≤6000 rpm (mechanical)
Corrosion protection
- IEC 60068-2-52 Salt mist
- for ambient conditions CX (C5-M) according to ISO 12944-2
Approximate weight
- 3.2 kg (HEK8/ÖLFLEX without cable)
- 3.9 kg (terminal box)
Explosion protection
- II 3 G Ex ec IIC T4 Gc (gas)
- II 3 D Ex tc IIIC T135°C Dc (dust)
- (only with option ATEX)
Operating temperature
- -40...+80 °C (cable HEK 8 fixed)
- -20...+80 °C (cable HEK 8 moved)
- -40...+90 °C, UL up to +80 °C (cable ÖLFLEX)
- -40...+100 °C (terminal box)
- >3072 pulses: up to -25 °C
Operating torque (typical)
6 Ncm
Permissible shaft load
- ≤450 N axial
- ≤600 N radial
Rotor moment of inertia
360 gcm²
Technical Data - Electrical Values
Approval
- CE
- UL approval / E217823
Phase shift
90 ° ±20°
Shaft isolation
Suitable up to 2.8 kV
Supply voltage
- 9...30 VDC
- 5 VDC ±5 %
Reference signal
Zero pulse, width 90°
Emitted interference
EN 61000-6-3
Consumption w/o load
≤100 mA
Duty cycle
40…60 %
Transmission length
- ≤350 m at 100 kHz (HTL-P)
- ≤550 m at 100 kHz (TTL)
Detection method
Optical
Output stages
- HTL-P (heavy-duty line driver)
- TTL/RS422
Output frequency
- ≤120 kHz
- ≤300 kHz (on request)
Output signals
K1, K2, K0 + inverted
Interference immunity
EN 61000-6-2
Pulses per revolution
300 … 5000
Documents
build
Mounting instructions
PDF · Baumer_HOG10-NIRO-HEK_T1_DE_EN_202210_MI_11055735.pdf
open_in_new Open
build
Mounting instructions
PDF · Baumer_HOG10-NIRO-KLK_DE_EN_202210_MI_11228280.pdf
open_in_new Open
verified_user
Declaration of Conformity – CE
PDF · Baumer_Encoder_Size_10_ML_DoC_81376584.pdf
open_in_new Open