Article No
11725691
Product Group
Inductive proximity switch
Housing
- 8 mm x 20 mm
- Metal
- Flush
Baumer
Inductive proximity switches
I81.P02S-F20.NO1Z.7WCV Inductive proximity switch
Baumer I81.P02S-F20.NO1Z.7WCV features NPN make function (NO) output, 1.5 … 2.5 mm sensing range, IP 67 protection class, cable connection and -25 … +75 °C operating temperature.
Technical Specifications
Article No
11725691
Product Group
Inductive proximity switch
Housing
- 8 mm x 20 mm
- Metal
- Flush
Detection Distance Max.
- 2 mm
- ≤ 81 % of Sn
Features
- NPN (NO)
- Cable
- -25 … +75 °C
- IP 67
Product Description
- Rectangular miniature sensor for tight spaces
- Lowest serial dispersion due to end-of-line calibration
- Robust even in demanding environments
- Temperature and long-term stable switching behavior
Detailed Technical Data
CABLE
Shielded
No
Insulation
Material: PVC
Wire cross-section
0.14 mm²
Cable diameter
3.0 mm
Cable length
200 cm
External sheath: Material
Material: PVC
Bending radius (fixed)
3 × outer diameter
Bending radius (moving)
10 × outer diameter
General Data
Hysteresis
3 … 20 % of Sr
Mounting type
Flush
Reference target
Fe360 8 x 8 x 1 mm
Temperature drift
± 10 % of Sr
Output indicator
Red LED
Typical correction factor
Soft steel 100 %, stainless steel 75 %, aluminium 50 %, copper 45 %
Actual sensing range Sr
± 10 % von Sn
Nominal sensing range Sn
2 mm
Assured sensing range Sa
≤ 81 % of Sn
Mechanical Data
Dimension
8 mm
Design
Rectangle
Housing material
Cast zinc-nickel-plated
Housing length
20 mm
Connection types
Cable, L=2 m
Max. tightening torque
0.8 Nm
Material (detection surface)
PBT
Ambient conditions
Shock resistance
IEC 60068-2-27:2009 100 g / 6 ms, 10 jolts per axis and direction
Protection class
IP 67
Vibration resistance
IEC 60068-2-6:2008 10 g at f = 10–2000 Hz, duration 150 min on each axis
Storage temperature
-25 … +75 °C
Operating temperature
-25 … +75 °C
Electrical Data
Output current
200 mA
Output circuit
NPN trigger function (NA)
Switching frequency
5 kHz
Short-circuit protection
Yes
Voltage drop Vd
<2 VDC
Reverse polarity protection
Yes
Supply voltage range +Vs
6 … 36 VDC
Max. current consumption (no load)
12 mA
SAFE MAXIMUM VALUES
MTTF
1,105 years
Diagnostic coverage (DC)
0 %
Documents
verified
Type Examination Certificate / Type approval – MTTF
PDF · MTTF_11725691.pdf
open_in_new Open
electrical_services
EPLAN macro (EPLAN Data Portal)
WEB · dataportal.eplan.com/part-details/bau.11725691