Article No
11116607
Product Group
- Inductive proximity switch
- factor 1
- all metals
Detection Distance Max.
- 2 mm
- ≤ 81 % of Sn
Baumer
Inductive proximity switches
IR08.P02F-F46.NO1Z.7SL Inductive proximity switch
Baumer IR08.P02F-F46.NO1Z.7SL features NPN make function (NO) output, 1.5 … 2.5 mm sensing range, IP 67 protection class, connector connection and -25 … +75 °C operating temperature.
Technical Specifications
Article No
11116607
Product Group
- Inductive proximity switch
- factor 1
- all metals
Housing
- 8 mm x 46 mm
- Stainless steel (V2 / A)
- Factor 1
- Flush
Detection Distance Max.
- 2 mm
- ≤ 81 % of Sn
Features
- NPN (NO)
- Connector
- -25 … +75 °C
- IP 67
Product Description
- Cylindrical standard housing for versatile use
- Factor 1 - Same high distances on any metal
- Lowest serial dispersion due to end-of-line calibration
- Robust even in demanding environments
- Temperature and long-term stable switching behavior
Detailed Technical Data
General Data
Special type
Factor 1
Hysteresis
3 … 20 % of Sr
Mounting type
Flush
Reference target
Fe360 8 x 8 x 1 mm
Temperature drift
± 10 % of Sr
Output indicator
Red LED
Typical correction factor
Soft steel 100 %, stainless steel 100 %, aluminium 100 %, copper 100 %
Actual sensing range Sr
± 10 % von Sn
Nominal sensing range Sn
2 mm
Assured sensing range Sa
≤ 81 % of Sn
Mechanical Data
Dimension
8 mm
Design
Cylindrical gear
Weight
13 g
Housing material
Stainless steel (V2A)
Housing length
46 mm
Connection types
M8 connector, 3-pin
Max. tightening torque
7 Nm
Material (detection surface)
PBT
Ambient conditions
Shock resistance
IEC 60068-2-27:2009 100 g / 6 ms, 10 jolts per axis and direction
Protection class
IP 67
Vibration resistance
IEC 60068-2-6:2008 10 g at f = 10–2000 Hz, duration 150 min on each axis
Storage temperature
-40 … +75 °C
Operating temperature
-25 … +75 °C
Electrical Data
Output current
200 mA
Output circuit
NPN trigger function (NA)
Switching frequency
3 kHz
Short-circuit protection
Yes
Voltage drop Vd
<2 VDC
Reverse polarity protection
Yes
Supply voltage range +Vs
5 … 36 VDC
Max. current consumption (no load)
12 mA
SAFE MAXIMUM VALUES
MTTF
775 years
Diagnostic coverage (DC)
0 %
Documents
verified
Type Examination Certificate / Type approval – MTTF
PDF · MTTF_11116607.pdf
open_in_new Open
electrical_services
EPLAN macro (EPLAN Data Portal)
WEB · dataportal.eplan.com/part-details/bau.11116607