Article No
11725036
Product Group
Inductive proximity switch
Housing
- 8 mm x 46 mm
- Stainless steel (V2 / A)
- Non-flush
Baumer
Inductive proximity switches
IR08.P04S-N46.NC1Z.7SL Inductive proximity switch
Baumer IR08.P04S-N46.NC1Z.7SL features NPN break function (NC) output, 2.5 … 5 mm sensing range, IP 67 protection class, connector connection and -25 … +75 °C operating temperature.
Technical Specifications
Article No
11725036
Product Group
Inductive proximity switch
Housing
- 8 mm x 46 mm
- Stainless steel (V2 / A)
- Non-flush
Detection Distance Max.
- 4 mm
- ≤ 81 % of Sn
Features
- NPN (NC)
- Connector
- -25 … +75 °C
- IP 67
Product Description
- Cylindrical standard housing for versatile use
- Non-flush design for an increased sensing distance
- Lowest serial dispersion due to end-of-line calibration
- Robust even in demanding environments
- Temperature and long-term stable switching behavior
Detailed Technical Data
General Data
Hysteresis
3 … 20 % of Sr
Mounting type
Non-flush
Reference target
Fe360 12 x 12 x 1 mm
Temperature drift
± 10 % of Sr
Output indicator
Red LED
Typical correction factor
Soft steel 100 %, stainless steel 70 %, aluminium 50 %, copper 45 %
Actual sensing range Sr
± 10 % von Sn
Nominal sensing range Sn
4 mm
Assured sensing range Sa
≤ 81 % of Sn
Mechanical Data
Dimension
8 mm
Design
Cylindrical gear
Housing material
Stainless steel (V2A)
Housing length
46 mm
Connection types
M8 connector, 3-pin
Max. tightening torque
7 Nm
Material (detection surface)
PBT
Ambient conditions
Shock resistance
IEC 60068-2-27:2009 100 g / 6 ms, 10 jolts per axis and direction
Protection class
IP 67
Vibration resistance
IEC 60068-2-6:2008 10 g at f = 10–2000 Hz, duration 150 min on each axis
Storage temperature
-40 … +75 °C
Operating temperature
-25 … +75 °C
Electrical Data
Output current
200 mA
Output circuit
NPN interrupt function (NC)
Switching frequency
5 kHz 0
Short-circuit protection
Yes
Voltage drop Vd
<2 VDC
Reverse polarity protection
Yes
Supply voltage range +Vs
6 … 36 VDC
Max. current consumption (no load)
12 mA
SAFE MAXIMUM VALUES
MTTF
1073 years
Diagnostic coverage (DC)
0 %
Documents
verified_user
Declaration of Conformity – CE
PDF · Baumer_IR06_IR08_ML_DoC_81164105.pdf
open_in_new Open
verified
Type Examination Certificate / Type approval – MTTF
PDF · MTTF_11725036.pdf
open_in_new Open
electrical_services
EPLAN macro (EPLAN Data Portal)
WEB · dataportal.eplan.com/part-details/bau.11725036
open_in_new Open